¾R detect: When the port doesn't connect with any PD, the POE switch will poll each port and detects the resistor.
。Dsvry R (ohms): display resistance value.
。Port Curr (mA): display current value.
。Port Volt (V): display voltage value.
。Port Pwr (W): display watt value.
。Class Curr(mA): display power class. When you enable the "Bypass classification" function, the class value will not show in here.
。Firmware Version: display the system firmware version.
。Total Port Power (W): total of all the port power that provided to PD.
。Power Management: status of the power management function.
。Total Power Limit: total power of the total ports' output power.
Commands
。Select command: enter the POE command number or Power supply management command integer in the prompt and press enter. The Power supply management command will show up when the Port PwrLimit Mangag. is enabling.
Command
[1]Power Management (Enable)[2]Set Port Enable (ON/OFF)[3]. Set Port PwrLimitClass. (ON/OFF)Description
Enabling or disabling the POE power management function.
Enabling or disabling the port POE inject function
Enabling or disabling per port power output limit. When is enabling, per port power output limit will follow the value that set in power limit max.
Enabling or disabling the port power limit management for power supply management.
Enabling the port power legacy detect.
Set port priority for the power supply management.
Set the port power output limit value. The maximum value must less than 15400.
Enabling or disabling auto refresh system parameters.