Error

Sub-

Error

Subcode

Compo-

Corrective Action

Code

code

Description

Description

nent

 

(hex)

 

 

 

 

 

 

2

 

Drive is clamped, can

Drive, drive

Replace Drive, drive cables

 

 

 

not unclamp (checking

cables

 

 

 

 

move to a drive)

 

 

 

 

 

 

 

 

38

1

Drive in service

In service state,

 

Follow operating instructions

 

 

state

attempting to turn drive

 

 

 

 

 

off in maint menu

 

 

 

 

 

 

 

 

 

2

 

In service state,

 

 

 

 

 

attempting to turn drive

 

 

 

 

 

on in maint menu

 

 

 

 

 

 

 

 

 

3

 

In service state,

 

 

 

 

 

attempting to put drive

 

 

 

 

 

in service state via

 

 

 

 

 

SCSI command

 

 

 

 

 

 

 

 

39

1

Drive not in ser-

Restoring drives, not in

 

Follow operating instructions

 

 

vice state

a service state

 

 

 

 

 

 

 

 

3F

1

Drive Addr con-

Address conflict with

 

Correct address in setup con-

 

 

flict

changer

 

figuration

 

 

 

 

 

 

 

2

 

Address conflict with

 

 

 

 

 

another drive

 

 

 

 

 

 

 

 

40

1

Not supported

Attempt to put drive in

 

 

 

 

by bus config.

service state via SCSI,

 

 

 

 

 

drive not supported by

 

 

 

 

 

current bus config.

 

 

 

 

 

 

 

 

 

2

 

Attempt to restore drive

 

 

 

 

 

via SCSI, drive not sup-

 

 

 

 

 

ported by current bus

 

 

 

 

 

config.

 

 

 

 

 

 

 

 

41

1

Drives overheat-

Warning for an over

Cabinet

Check room temp

 

 

ing

heating drive

Temp

 

 

 

 

 

 

 

42

1

Drives shut-

Drive will be shutdown

Cabinet

Check room temp

 

 

down - heat

due to overtemp condi-

Temp

 

 

 

 

tion, alert host of 90 sec

 

 

 

 

 

delay before shutdown

 

 

 

 

 

 

 

 

43

1

Low fan speed-

Warning for low fan

Fan

Replace fan

 

 

drive

speed in a drive module

 

 

 

 

 

 

 

 

44

1

Drive shutdown-

Drive will be shutdown

Fan

Replace fan

 

 

fan

due to fan failure, alert

 

 

 

 

 

host of 90 sec delay

 

 

 

 

 

before shutdown

 

 

 

 

 

 

 

 

Plasmon D875 - D2175 User Manual

Appendix D

Document Revision E

Page 73

Page 75
Image 75
Plasmon D875, D2175 user manual Figuration