TROUBLESHOOTING

Troubleshooting Symptoms

Engine Lacks Power

POSSIBLE CAUSE

SOLUTION

 

 

Air filter restricted

Clean or replace air filter(s)

 

 

Bad fuel; generator stored

Drain the fuel system and refuel

without treating or draining

 

petrol, or refueled with bad

 

petrol

 

 

 

Mechanical failure

Take the generator to an authorized POLARIS servicing

 

supplier or refer to the service manual

 

 

Engine Backfires

POSSIBLE CAUSE

SOLUTION

 

 

Weak spark from spark plug

Inspect, clean, and / or replace spark plug

 

 

Incorrect spark plug gap or

Set gap to specification or replace plug

heat range

 

 

 

Old or non-recommended

Drain the fuel system and refuel

fuel

 

 

 

Incorrectly installed spark

Take the generator to an authorized POLARIS servicing

plug wires

supplier or refer to the service manual

 

 

Incorrect ignition timing

Take the generator to an authorized POLARIS servicing

 

supplier or refer to the service manual

 

 

Mechanical failure

Take the generator to an authorized POLARIS servicing

 

supplier or refer to the service manual

 

 

Loose ignition connections

Check all connections and tighten

 

 

Water present in fuel

Drain the fuel system and refuel

 

 

67

Page 68
Image 68
Polaris P2000i, P1000i manual Engine Lacks Power, Engine Backfires