OPERATION

Safe Operating Precautions

Power Management

 

RUNNING

ADDITIONAL

DEVICE

STARTING (SURGE)

(RATED) WATTS

 

 

WATTS

Paint Sprayer

360

1080

 

 

 

Radio

300

300

 

 

 

Total Running (Rated) Watts = 660

Additional Starting Surge Watts = 1380

Total Generator Output Required = 2040

Ensure the combined electrical rating of the powered device(s) do not exceed the maximum allowed by the generator. Never exceed the maximum power rating of the generator. Power levels between rated and maximum may be used for no more than 30 minutes.

DC Operation

Connecting the Battery Charging Cable (included)

The battery emits explosive hydrogen gas during normal operation. A spark or flame can cause the battery to explode with enough force to kill or cause serious injury. Wear protective clothing and eye protection when charging a battery.

Battery posts, terminals, and related accessories contain lead and lead components. Wash hands after handling.

The DC charging output is not regulated. The DC receptacle should only be used for charging 12V DC batteries.The 12V DC receptacle has no battery overcharge protection function. Do not overcharge the battery.

When using the DC output, position the SMART throttle switch to OFF. The DC receptacle may be used while the AC power is in use.

34