20. Specifications
CODING FORMATS
| DX CODE  | 1,048,567 Codes | 
| DXS CODE  | 1,048,567 Codes | 
POWER REQUIREMENTS
| PRIMARY SUPPLY | |
| 
 | Input: 120 VAC 60 Hz | 
| 
 | Output: 14 VDC 1.7 Amps Maximum | 
| BACKUP SUPPLY | 7.2 Volt 2 Amp/Hour  | 
| BACKUP OPERATION DURATION | 24 Hours Minimum | 
| BATTERY LIFE EXPECTED | 3 Years | 
RF CHARACTERISTICS
| RECEIVER TYPE | |
| RF SENSITIVITY | |
| RADIO FREQUENCY | 315 Mhz | 
| MAXIMUM RANGE | 1000 Feet  | 
COMMUNICATOR
| 4 x 2, | |
| 
 | ADEMCO Contact ID | 
| 
 | SIA | 
| 
 | UL Tested with SURGARD | 
| 
 | |
| 
 | Central Station Receiver | 
| PSTN DIALING | Tone or Pulse | 
| DIALING / IP REPORTING DELAY | 0 or 15 Seconds | 
| IP REPORTING FORMATS | Surgard System  | 
| 
 | Surgard System  | 
| 
 | Surgard System  | 
| REMOTE PROGRAMMING PASSWORD | 6 Digits | 
| REMOTE COMMUNICATIONS PASSWORD | 4 Digits | 
| ACCOUNT NUMBER LENGTH | SurGard FIBRO IP (SIA)  | 
| 
 | PSTN/SIA  | 
| 
 | PSTN/CID and 4 by 2  | 
| PRIMARY TELEPHONE NUMBER | 20 Digits | 
| SECONDARY TELEPHONE NUMBER | 20 Digits | 
| SUPERVISORY TELEPHONE NUMBER | 20 Digits | 
| CONSOLE STATUS REPORT | Optional 1, 7 or 30 Day Report | 
| IP ADDRESSING | IPv4 Addressing Only | 
CONSOLE
| OPERATING TEMPERATURE | |
| ACTIVITY TIMER PERIOD | Two Programmable Time Windows | 
| PSTN REPORTING AUDIO | |
| IP REPORTING AUDIO | |
| SIZE | 6.25” W x 2.85” H x 6.25” D (9.6” H with antenna up) | 
REGULATORY
| CONSOLE | Designed to conform to: | 
| 
 | UL 1635 Digital Alarm Communicator | 
| 
 | UL 1637, Home Healthcare Signaling Device | 
| 
 | Smoke Signaling Accessory File S2499 / UL217 | 
| 
 | National Fire Protection Association (NFPA 72) | 
| 
 | ROHS | 
| POWER SUPPLY | CSA, ETL, FCC, Effi ciency Level 4 | 
| EMISSIONS | FCC Part 15 & Part 68, Industry Canada | 
38