18. Appendix B - Mode Table

SYSTEM EVENT

Fire & CO Alarms

Fire & CO Supervisory Timeout [2]

Fire & CO Sensor Low

Battery [2]

Console (HELP button) Alarm

Emergency Sensor Alarm

Emergency Sensor Supervisory Timeout [2]

Emergency Sensor Low

Battery [2]

Console Trouble [2] & [5]

Communication Status (telephone/cell)

Module Status

Activity Monitor

Temperature Alarms

Missed Reminder Messages

Entering Mode

CONSOLE OPERATING MODE

 

HOME MODE

 

 

AWAY MODE

 

 

NIGHT MODE

 

 

 

(Overrides Night Mode)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Reports to Central Station

Voice Announcement

Starts 2-Way Audio

Reports to Central Station

Voice Announcement

Starts 2-Way Audio

Reports to Central Station

Voice Announcement

Starts 2-Way Audio

Yes

Yes

~ If Enabled [6]

Yes

Yes

~ If Enabled [6]

Yes

Yes

~ If Enabled [6]

Yes

~ If Enabled [8]

N/A

Yes

No

N/A

Yes

No

N/A

Yes

~ If Enabled [8]

N/A

Yes

No

N/A

Yes

No

N/A

Yes

Yes

~ If Enabled

Yes

Yes

~ If Enabled

Yes

Yes

~ If Enabled

Yes

Yes

~ If Enabled [6]

Yes

Yes

~ If Enabled [6]

Yes

Yes

~ If Enabled [6]

~ If Enabled

~ If Enabled [8]

N/A

No [1]

No [1]

N/A

~ If Enabled

No

No

Yes

~ If Enabled [8]

 

Yes

No [1]

 

Yes

No

 

N/A

N/A

N/A

Yes

~ If Enabled

 

Yes

No

 

Yes

No

 

N/A

N/A

N/A

[8] & [9]

 

 

 

 

 

 

 

 

No

Yes

N/A

No

Yes

N/A

No

No

N/A

 

Yes

 

 

No

 

 

No

 

N/A

N/A

N/A

N/A

N/A

N/A

Yes

Yes

~ If Enabled [7]

No

No

No

Yes

Yes

~ If Enabled [7]

~ If Enabled [4]

~ If Enabled [4]

~ If Enabled [4]

~ If Enabled [3]

~ If Enabled [3]

~ If Enabled [3]

~ If Enabled [3]

~ If Enabled [3]

~ If Enabled [3]

Yes [11]

Yes

~ If Enabled

No

No

No

Yes [11]

Yes

~ If Enabled

Yes

From Away

N/A

Yes

Yes

N/A

From Away

From Away

N/A

Mode Only [10]

Mode Only

Mode Only

 

 

 

 

 

 

Mode Table Notes:

[1] Setting the Console in Away Mode clears all supervisory events for emergency sensors only. Supervisory timers for Smoke detectors, CO detectors, and activity monitor sensors are not affected; switching to Home or Away Mode constitutes activity.

[2] Supervisory events are reported by automatic status reports regardless of the global REPORT SUPERVISORY EVENTS setting. Also, AC power loss events are reported by automatic status reports regardless of the global REPORT AC FAIL setting. Both settings are on the Reporting Options tab.

[3] If ENABLE HOME MODE ONLY is selected for TEMPERATURE LIMIT SETTINGS on the Console tab, temperature alarms will not occur in this mode. Select ENABLE to allow temperature alarms in this mode.

[4] Either ENABLE or ENABLE HOME MODE ONLY needs to be selected on the Console tab for TEMPERATURE LIMIT SETTINGS to allow temperature alarms.

[5] Console supervisory faults are always reported, but not annunciated in Away Mode and Night Mode.

[6] To start a two-way audio session after a report is triggered by an emergency alarm sensor, two-way audio must be globally enabled in TWO-WAY AUDIO MODE on the Reporting Options tab and enabled for the sensor’s zone with the TWO-WAY AUDIO check box on the Sensors tab.

[7] For activity sensors, two-way audio is enabled globally in TWO-WAY AUDIO MODE on the Reporting Options tab regardless of the activity sensor’s zone setting with the TWO-WAY AUDIO check box on the Sensors tab.

[8] To enable Console/sensor zone low battery and sensor zone supervision annunciations, ANNUNCIATE TROUBLE INDICATION must be selected on the Console tab.

[9] To announce telephone line and AC power status, ANNUNCIATE PHONE-LINE/AC STATUS must be selected on the Console tab.

[10] The Console will only announce Home Mode when manually switched from Away Mode using the HOME button.

[11] To report missed reminder messages, the global REPORT MISSED REMINDER option must be selected on the Reminder Messages tab and the reminder message slot must have the SEND REPORT option selected.

36