19. Appendix C - Communications Status Window Table

Below are possible messages that may appear in the communications status window when RA4200 is connected to a PERS-4200 Console.

Opening Port COM30

Initializing Com Port

Sending password

Login Success

Get status data

Console Type: Standard Console Protocol Ver: 5 Hardware Ver: 0 Firmware Ver: 2.4.0

Data Version (zone-panel-reminder-log-time-IP- MiscConfi g1): -1-3-1-3-1-2-2

Console (PSTN) Account Number: 007152 Console AC: Good

Console Battery: Good

Console Mode: Home Sensor Low Battery: Sensor Supervision Trouble: Done Get Status

‘CONNECT’ (no EXP. MODULES):

Opening Port COM30

Initializing Com Port

Sending password

Login Success

Get status data

Console Type: Standard Console

Protocol Ver: 5

Hardware Ver: 0

Firmware Ver: 2.4.0

Data Version (zone-panel-reminder-log-time-IP- MiscConfi g1): -1-3-1-3-1-2-2

Console (PSTN) Account Number: 007152

Console AC: Good

Console Battery: Good

Console Mode: Home

Sensor Low Battery:

Sensor Supervision Trouble:

Done Get Status

‘GET CONSOLE’:

Get time data

Get zone data

Get console data

Get reminder data

Get IP confi guration

Cellular Signal Strength (dBm): 0

Get IP status data

Cellular Status:

Cellular Network:

Cellular Roaming: Get status data

Console Type: Standard Console Protocol Ver: 5

Hardware Ver: 0

Firmware Ver: 2.4.0

Data Version (zone-panel-reminder-log-time-IP- MiscConfi g1): -1-3-1-3-1-2-2

Console (PSTN) Account Number: 007152

Console AC: Good

Console Battery: Good

Console Mode: Home

Sensor Low Battery:

Sensor Supervision Trouble:

Get Misc Confi g 1

Done Get Console

‘GET CONSOLE’ (CELL MODULE PRESENT):

Opening Port COM30

Initializing Com Port Sending password Login Success Get status data

Console Type: Standard Console Protocol Ver: 5

Hardware Ver: 0

Firmware Ver: 2.4.0

Data Version (zone-panel-reminder-log-time-IP- MiscConfi g1): -1-3-1-3-1-2-2

Console (PSTN) Account Number: 007152 Console AC: Good

Console Battery: Low

Console Mode: Home Sensor Low Battery:

Sensor Supervision Trouble: -1-2

Done Get Status

Get time data

Get zone data

Get console data

Get reminder data

Get IP confi guration

Cellular Signal Strength (dBm): -91

Get IP status data

Cellular Status: ---

Cellular Network: AT&T

Cellular Roaming: ---

Get status data

Console Type: xxxxxx Console Protocol Ver: 5 Hardware Ver: 0 Firmware Ver: 2.4.0

Data Version (zone-panel-reminder-log-time-IP- MiscConfi g1): -1-3-1-3-1-2-2

Console (PSTN) Account Number: 007152

Console AC: Good

Console Battery: Low

Console Mode: Home

Sensor Low Battery:

Sensor Supervision Trouble: -1-2

Get Misc Confi g 1

Done Get Console

‘SET CONSOLE’:

Set zone data

Set console data

Set IP Confi guration

Set reminder data

Set Misc Confi g 1

Done Set Console

‘GET LOG’:

Get log data

‘SAVE’:

Saving C:\Linear\RA4200\Accounts\Account1.ra1

‘DISCONNECT’:

Terminate call

Hanging up / Closing session

Terminating... Please wait a few seconds.

Wait Done.

‘OPEN’:

Opening C:\Linear\RA4200\Accounts\Account1.ra1

Tools->Clear Event Log:

Done Clearing Log

Tools->Test IP Reporting

Test IP reporting request sent

Tools-> File functions (when operation is cancelled):

SSH fi le transfer cancelled.

Tools -> Export file to Voice Gateway

SSH fi le transfer error. or

SSH export fi le transfer success.

Tools -> Retrieve Import file from Voice Gateway

SSH fi le transfer error. or

SSH import fi le transfer success.

Tools->Merge Import

No merging error. or

Merging errors encountered.

37

Page 39
Image 39
Linear PERS-4200 Series manual Appendix C Communications Status Window Table, Opening Port COM30