The RMX 4000 is designed with ease of maintenance in mind. Most components are swappable and are accessible directly via the front panel

or the rear panel.

The MPM+/MPMx, power supplies and Fan tray are Hot Swappable. The Fan tray must be replaced immediately or the temperature spike in the RMX shall initiate a shutdown. The RTM-IP 4000, RTM ISDN, RTM LAN, Fabric Switch Module (FSM) 4000 and the CTNL 4000 are not Hot Swappable. System shutdown is required when replacing the RTM-IP 4000, RTM ISDN, RTM LAN, FSM 4000 and the CTNL 4000.

The following components can be replaced when they are faulty:

CNTL 4000 Module, see "Replacing the CNTL 4000 Module” on page 2-4.

AC Power Supply Modules, see "Replacing an AC Power Supply Module” on page 2-5.

AC Power Entry Modules, see "Replacing an AC Power Entry Module (PEM)” on page 2-6.

DC Power Rail Modules, see "Replacing a DC Power Rail Module (PRM)” on page 2-7.

Fan drawer, see "Replacing the Fan Drawer” on page 2-9.

Adding an Air Filter, see "Inserting an Air Filter (Optional) in the Fan Drawer” on page 2-10.

MPM+/MPMx card. This card is hot-swap enabled. See "Replacing an Faulty MPM+/MPMx Card” on page 2-11.

RTM ISDN card, see "Replacing a RTM ISDN Card” on page 2-14.

RTM-IP 4000 card, see "Replacing the RTM-IP 4000” on page 2-16.

RTM LAN card, see “Replacing the Fabric Switch Module (FSM 4000)” on page 2-18.