Polycom DOC2559A manual Replacing an AC Power Supply Module

Models: DOC2559A

1 65
Download 65 pages 53.98 Kb
Page 51
Image 51

Polycom RMX 4000 Hardware Guide

Replacing an AC Power Supply Module

Two units supply power to the RMX 4000 (3rd optional - AC only), each unit with its own power cord. Use the following procedure to replace a

Power Supply unit:

Please verify the type of power supply used on your RMX 4000. Do not insert a different type of power supply than the current type installed on your system.

1Unscrew the captive screws on the front panel of the Power Supply unit that secures the unit to the chassis.

2Using your right hand, press your thumb on the pressure latch and with your fingers inserted in the hand grip (on top), pull the Power Supply unit out.

Place thumb

Finger grip

here

 