Hardware Installation Guide for the Polycom SoundStructure C16, C12, C8, And SR12

Rack-Mounting The Polycom SoundStructure Device

The Polycom SoundStructure can be mounted in an equipment rack, or placed on a tabletop or other flat surface, or mounted under the table with the optional undertable mounting kit.

Each SoundStructure device requires one rack space and does not require additional empty rack spaces above or below the device.

When multiple devices are racked together, before final tightening of the rack mount screws on each device after the first one, ensure there is enough clearance so that the front-panel door will open freely.

To rack-mount the SoundStructure unit:

1.

Remove the four front screws on the enclosure.

 

 

SoundStructure C16

 

2.

Align the rack ears, and install the rack ears using the screws that were

 

removed from the enclosure.

 

 

SoundStructure

C16

3.

Mount the equipment in the rack and secure with the four supplied rack

 

mount screws (screw size is 10-32x1/2").

 

SoundStructure

C16

To place on a tabletop or other flat surface:

>>If the equipment will not be mounted in an equipment rack, it is recommended that you install the four adhesive rubber feet on the bottom of the device (as shown below) before placing the equipment on furniture.

2 - 6