Hardware Installation Guide for the Polycom SoundStructure C16, C12, C8, and SR12

Thermal

•Thermal Dissipation (Btu/hr): 266 Btu/hr (C16), 230 Btu/hr (C12), 215 Btu/hr (SR12), 200 Btu/hr (C8)

•Operating temperature 0 - 40° C (104° F)

Inputs

•Phantom power: 48 V DC through 6.8 kOhm series resistor per leg, 7.5 mA per channel, software selectable

•Analog input gain: -20 to 64 dB on all inputs in 0.5 dB steps, software adjustable

•Maximum input amplitude: +20.4 dBu, 1% THD + N

•Nominal level: 0 dBu (0.775 Vrms)

•Equivalent input noise: <-122 dBu, 20-20,000 Hz, Rs=150 Ohms (1%)

•Input impedance: 10 kOhms

•Input EMI Filter: Pi filter on all audio inputs

Outputs

•Output gain: -100 to 20 dB in 1 dB steps, software adjustable

•Maximum output amplitude: +23 dBu, 1% THD + N

•Nominal output level: 0 dBu (0.775 Vrms)

•Output impedance: 50 Ohm, each leg to ground, designed to drive loads > 600 Ohms

•Output EMI filter: Pi filter on all audio outputs

System

Unless noted, all values are valid for all channels at 0 dB input gain.

•Frequency response: 20-22,000 Hz, + 0.1 /- 0.3 dB

•Idle channel noise: <-109 dB FS no weighting, 20-20,000 Hz, -60dB FS, 997 Hz input signal, 0 dB gain

•Dynamic range: >109 dB FS no weighting, 20 - 20,000 Hz, -60 dB FS, 997 Hz input signal, 0 dB gain

•Linearity: 0 dB FS to -122 dB FS +/- 1 dB

3 - 2

Page 32