POSIFLEX Business Machines PP3000 manual DEFINITION RANGE 1 ≤ n1 ≤ 127, 1 ≤ n2 ≤

Models: PP3000

1 78
Download 78 pages 26.37 Kb
Page 62
Image 62
CODES (HEX/CONTROL) : 19 / <EM>

FUNCTION : Immediate drive command for peripheral unit 2CODES (HEX/CONTROL) : 1A / <SUB>CODES (HEX/CONTROL) : 1B 07 n1 n2 / <ESC> <BEL> n1 n2FUNCTION : Adjust drive pulse width for peripheral unit 1DEFINITION RANGE : 1 ≤ n1 ≤ 127, 1 ≤ n2 ≤ 127CODES (HEX/CONTROL) : 1B 25 00 / <ESC> “%” <0>FUNCTION : Disable download character setManual background TM

CODES (HEX/CONTROL) : 19 / <EM>

FUNCTION : Immediate drive command for peripheral unit 2

APPLICATION LIMIT : Peripheral units 1 and 2 cannot be driven simultaneously.

DETAIL DESCRIPTION : Drives peripheral unit 2. Pulse width is fixed at 200ms with a fixed delay time of 200ms. Same as <SUB>.

CODES (HEX/CONTROL) : 1A / <SUB>

FUNCTION : Immediate drive command for peripheral unit 2

APPLICATION LIMIT : Peripheral units 1 and 2 cannot be driven simultaneously.

DETAIL DESCRIPTION : Drives peripheral unit 2. Pulse width is fixed at 200ms with a fixed delay time of 200ms.

APP. A STAR

CODES (HEX/CONTROL) : 1B 07 n1 n2 / <ESC> <BEL> n1 n2

FUNCTION : Adjust drive pulse width for peripheral unit 1

DEFINITION RANGE : 1 n1 127, 1 n2 127

APPLICATION LIMIT : Adjustment is not necessary for standard cash drawers in the U.S.A. market.

DETAIL DESCRIPTION : Adjusts drive pulse width for peripheral device #1 requiring other than standard 200 ms pulse time and recovery time.

Energizing time = 10 x n1 ms Recovery time = 10 x n2 ms Executed by <BEL> or <FS> code.

Printing and paper feed are prohibited throughout the energizing and recovery time.

CODES (HEX/CONTROL) : 1B 25 00 / <ESC> “%” <0>

FUNCTION : Disable download character set

DETAIL DESCRIPTION : Disable the selected download character set and selects the built-in character set. When the power for the printer is initially turned on, the built-in character set is selected.

A - 6

Page 62
Image 62
POSIFLEX Business Machines PP3000 manual DEFINITION RANGE 1 ≤ n1 ≤ 127, 1 ≤ n2 ≤, CODES HEX/CONTROL 19 / EM