Precor EFX534 owner manual Using Csafe Standard Equipment, User ID Entry Program Keys, Enter Reset

Models: EFX534

1 56
Download 56 pages 35.23 Kb
Page 26
Image 26

C O M M E R C I A L P R O D U C T S D I V I S I O N

Press Enter once again and the Error Log appears. The EFX stores the last ten errors that have been detected. Press any or key to view the error codes.

Note: If the EFX has no errors stored in memory, a “– – –” appears on the display.

To view the odometer reading at the time the error was detected and the hours of use at the time the error occurred, press the Select key while the error code is being displayed.The Select key acts as a toggle between the associated information.

To clear (delete) the error log, press QuickStart for at least four seconds while viewing the list. Prompts appear on the display and confirm (OK) that the error messages have been deleted (“cleared”) from memory.

Important:You cannot retrieve the error log once you have deleted it.

USING CSAFE STANDARD EQUIPMENT

The EFX is fully compatible with CSAFE protocols. Once the unit is connected to a CSAFE master device and the user maintains a stride rate above 40 strides per minute, he or she is prompted to enter an identification number (user ID).

Note: If the optional battery recharger is plugged into the EFX and connected to an appropriate power source, then no pedaling is necessary for user ID entry.

Five zeros appear on the display. The left zero indicates that it is awaiting input. The following table provides information about the keypad functions:

User ID Entry:

Program Keys

 

 

or

Enter

Reset

moves the blinking LED from field to field.

submits the displayed user ID. Note that if the five zeros are being displayed when the user presses Enter, the user ID entry is bypassed and the Course prompt appears.

resets the display to the Precor banner.

A message indicates when the user ID is accepted by the CSAFE master device. Then, the course prompt is displayed. See Quick Steps to Working Out on page 37.

Note: If the user’s stride rate drops below 40 strides per minute while using the CSAFE device connection, a prompt PEDAL FASTER appears. If the stride rate remains below the 40 strides per minute threshold for the next twenty seconds, the CSAFE connection is terminated. The word RESETTING appears on the display while the EFX disconnects from the CSAFE device.

To review information about CSAFE specifications, visit the web site at:

www.fitlinxx.com/csafe

Note: The EFX supports the CSAFE master device per the specifications found at the web site. However, exceptions do exist. If you have questions or need technical support, refer to Obtaining Service on page 7.

page 26

Page 26
Image 26
Precor EFX534 owner manual Using Csafe Standard Equipment, User ID Entry Program Keys, Enter Reset