Chapter 3 Error Messages

Error Messages

The RFID encoder can detect a number of errors. When one of these errors occurs, the RFID encoder alerts the printer to perform the currently selected error action (see “Error Handling” on

page 51) and display the appropriate error message on the control panel’s LCD (see Table 2).

Table 2. Control Panel Error Messages

Error Message

Explanation

Solution

 

 

 

 

 

 

RFID MAX RETRY

Error Handling = Overstrike in

Press PAUSE to clear the

Check System

the RFID CONTROL menu,

message.

 

and the Label Retry count has

See “Troubleshooting” on

 

been exhausted.

page 69.

 

 

 

RFID Comm Err

RFID error: communication

Press PAUSE to clear the

Check Cable

cannot be established with

message.

 

the RFID encoder. Reader

See “Troubleshooting” on

 

will be set to Disable in the

page 69.

 

RFID CONTROL menu and

 

 

the previous port settings

 

 

restored.

 

 

 

 

RFID TAG FAILED

Error Handling = Stop in the

Press PAUSE to clear the

Check Media

RFID CONTROL menu, and

message.

 

the RFID encoder could not

See “Troubleshooting” on

 

read the RFID tag.

page 69.

 

 

 

68

Page 68
Image 68