Chapter 4: Management with WebPAM PROe
83
Enclosure Settings
The Enclosure–Settings tab enables you to make settings for certai n component s
of the VTrak subsystem enclosure. To make Enclosure settings:
1. Click the Subsystem icon in Tree View.
2. Click on the Enclosures i con.
3. Click on the Enclosure ic on.
4. Click on the Settings tab in Management View.
5. Enter a polling interval (15 to 255 seconds) in the Polling Interval field.
6. Enter a value in the Enclosure Warning Temperature Threshold field.
7. Enter a value in the Enclosure Critical Temperature Threshold field.
8. Enter a value in the Controller Warning Temperature Threshold field.
9. Enter a value in the Controller Critical Temperature Threshold field.
10. Click the Submit button.
The changes take effect immediately.
FRU VPD
The Enclosure–FRU VPD tab displays Vital Product Data (VPD) information
about Field Replaceable Units (FRU) in the VTrak subsystem enclosure,
including:
Controller Motherboard
Battery Backup Unit (BBU)
Cooling Units
Power Supply Units
Back Plane
Use this information when communicating with Technical Support and when
ordering replacement units. For contact information, see “Contact Technical
Support” on page239.
To access Controller information:
1. Click the Subsystem icon in Tree View.
2. Click on the Enclosures i con.
3. Click on the Enclosure ic on.
4. Click on the FRU VPD tab in Management View.