Vtrak
Trademarks
Copyright
Important data protection information
Recommendations
Contents
Management with WebPAM PROe
Management with the CLU
Technology Background
Maintenance
Support
Troubleshooting
Appendix a Useful Information
Index
VTrak M310p, M210p Product Manual Viii
About This Manual
Introduction
VTrak M310p front view M210p is similar
Overview
Architectural Description
Features and Benefits
Feature Benefit
Maximum performance in Multi-Threaded
RAID
Specifications
FCC Statement
Unpack the VTrak
Installation
Rackmounted VTrak M310p M210p is similar
Mount VTrak in a Rack
Installation
Install Disk Drives
VTrak M310p/M210p drive carrier mounting holes
Drive Numbering
NIC
Connect Network and Data Cables
Serial connector for VTrak M310p/M210p
Set Up Serial Cable Connections
VTrak M310p/M210p front panel LED display
Connect the Power
VTrak M310p, M210p Product Manual
VTrak Setup with CLI or CLU
Setup
CLI
Administrator@cli net -a mod -t mgmt -s dhcp=enable
System Date and Time
CLU
Management Port
Exit the CLU
Log-in to WebPAM PROe
VTrak Setup with WebPAM PROe
Regular Connection
Secure Connection
Setup
VTrak M310p, M210p Product Manual
Language Selection
Automatic
Create a Disk Array
Express
VTrak M310p, M210p Product Manual
Advanced
VTrak M310p, M210p Product Manual
Setup
VTrak M310p, M210p Product Manual
Setup
VTrak M310p, M210p Product Manual
Log-out of WebPAM PROe
Internet Connection using WebPAM PROe
Additional Logical Drives
VTrak M310p, M210p Product Manual
Management with WebPAM PROe
VTrak Status Indicators
State LEDs Dark Steady Flashing Amber Red Green
Audible Alarm
Drive Status Indicators
LEDs State
Steady Flashing Amber Red Green
Https//192.168.10.148
Log-in/Log-out
Http//192.168.10.148
Management with WebPAM PROe
WebPAM PROe Opening Screen
Graphic User Interface
Function
Header
Language Selection
View
Contact Us
Storage Network
Tree View
Event Frame
Subsystems
Management Window
Subsystem Information
Subsystem Settings
Subsystem
View Events
Subsystem Events
Clear Events
Save Events
Start Background Function
Change Background Settings
Background Activities
Schedule an Activity
Scheduler
View Scheduled Activities
Delete an Activity
View Lock Status
Lock
Set Lock
Renew Lock
Release Lock
Administrative Tools
User Information
User Settings Administrator
User Management
User Event Subscription
User Settings User
Smart
List of User Notification Events
Create a User
User Password Administrator
User Password Users
List of User Privileges
Delete a User
User Sessions
Network Management
Scsi Channel Information
Scsi Channel Settings
Scsi Management
View LUN Map
Storage Services
Scsi Target Information
LUN Mapping Parameters
Software Management
Edit a LUN Map
Manual Start, Restart, Stop
Change Email Setting
Send a Test Message
Web Server
Click on the Web Server Setting link
Telnet
Change Start Setting
Change Start Setting
Snmp
CIM
Netsend
CIM Service Settings
Add Recipients
Delete Recipients
Export
Import
Firmware Update
Clear Statistics
Restore Factory Defaults
Shutdown
Shutdown and Restart
Monitor the Shutdown
Restart the Subsystem
Monitor the Restart
Controllers
Controller Information
Controller
Controller Statistics
Clear Statistics
Controller Settings
Identify Enclosure
Enclosures
Enclosure Information
Enclosure
FRU VPD
Enclosure Settings
Battery Recondition
Battery
Silence Buzzer
Change Buzzer Settings
Buzzer
Identify a Physical Drive
Physical Drives Settings
Physical Drives
Advanced Physical Drive Information
Physical Drive
Physical Drive Information
Identify a Physical Drive
Physical Drive Statistics
Clear Physical Drive Conditions
Physical Drive Settings
Force a Physical Drive Offline/Online
Physical Drive Media Patrol
Disk Arrays
Create a Disk Array Express
Create a Disk Array Automatic
Management with WebPAM PROe
Logical Drive Creation
Create a Disk Array Advanced
Disk Array Creation
Summary
Delete a Disk Array
Disk Array Information
Disk Array
Disk Array Status
Physical Drives in the Disk Array
Logical Drives in the Disk Array
Create a Logical Drive
Disk Array Settings
Management with WebPAM PROe
Disk Array Migration
Delete a Logical Drive
Disk Array Rebuild
Manual Rebuild
Disk Array Background Activity
View Progress of Background Function
Transition
Transport
Logical Drives
Logical Drive Status
Logical Drive Information
Logical Drive
Logical Drive Statistics in alphabetical order
Logical Drive Settings
Logical Drive Initialization
Logical Drive Background Activity
Logical Drive Synchronization
Logical Drive Redundancy Check
Logical Drive Check Table
Logical Drive PDM
LUN Mapping Parameters
Logical Drive LUN Settings
Spare Drives
Delete Spare Drive
Create Spare Drive
Spare Drive Information
Spare Check All Spare Drives
Spare Drive
Locate a Spare Drive
Spare Drive Settings
Spare Check Individual Spare Drive
Logical Drive Summary
VTrak M310p, M210p Product Manual 118
Management with the CLU
State LEDs Dark Steady Flashing Amber Red Green
Audible Alarm
Serial Connection
CLU Connection
Telnet Connection
Telnet 192.168.1.56
123
Exit the CLU
CLU Function Map
126
127
128
129
130
131
Subsystem Management
Quick Setup
Alias
Media Patrol
Controller Management
System Date and Time
Physical Drive Coercion
Controller Settings
Alias
Enclosure Management
Power Supply Units
Enclosure Status
Enclosure Management
Temperature Sensors
Enclosure Settings
Blowers
Voltage Sensors
Polling Interval
Temperature Thresholds
Batteries
Physical Drive Management
Global Physical Drive Settings
Locate Enclosure
Write Cache
Individual Physical Drive Settings
Locate Physical Drive
Force Physical Drive Offline/Online
Disk Array Management
Highlight Save Settings and Continue and press Enter
Delete a Disk Array
Disk Array Information
Disk Array Settings and Functions
Media Patrol
Rebuild
Predictive Data Migration
Migration
Accept Incomplete Array
Locate Disk Array
Create a Logical Drive
Delete a Logical Drive
Logical Drive Management
Logical Drive Settings and Functions
Logical Drive Information
Write Cache Policy
Redundancy Check
Initialization
Network Management
Management Port Settings
Locate Logical Drive
Manual
Channel Information
Channel Settings
Scsi Management
Target Information
Background Activity
Background Activities List
Background Activity Settings
Nvram Events
Event Viewer
Runtime Events
Create New Spare Drive
Additional Info and Management
Spare Drive Management
Delete Spare Drive
LUN Mapping
Create New User
User Settings Privilege and Status
Password
User Settings Display Name and Email Address
Delete User
Webserver
161
Snmp Trap Sinks
Highlight Create New Message Recipient and press Enter
Netsend Recipients
Flash through Tftp
Restart over Telnet
Shutdown over Telnet
Shutdown over Serial
Restart over Serial
Buzzer
Maintenance
Your PC
Firmware Update WebPAM PROe
Tftp Server
Restart VTrak
Firmware Update CLU
VTrak M310p/M210p power supply
Replace Power Supply
Replace Cooling Unit Blower
Electrical connector
174
Replace Cache Battery
Remove this screw
Maintenance
Replace RAID Controller
Introduction to RAID
Technology Background
RAID 0 Striping interleaves data across multiple drives
RAID 0 Stripe
Data Mirror Disk Drives
RAID 1 Mirror
RAID 1E Enhanced Mirror
RAID 5 Stripes all drives with data and parity information
RAID 5 Block and Parity Stripe
RAID 6 Block and Double Parity Stripe
RAID 10 Mirror + Stripe
RAID 50 Axles
RAID 50 Striping of Distributed Parity
Per Axle
No. of Drives No. of Axles RAID
Array
Advantages Disadvantages
Choosing a RAID Level
RAID 1E
190
Sector Size
Stripe Size
Read Cache Policy
Cache Policy
Cache Line Size
Capacity Coercion
Write Cache Policy
Hot Spare Drives
Initialization
RAID Level Migration
Partition and Format the Logical Drive
Performance
From Increase Redundancy Capacity
Add Lose
Ranges of Disk Array Expansion
Create a New Logical Drive
Media Patrol
Current LD Size Maximum LD Sector Size Expansion Size
PDM Triggers
Predictive Data Migration PDM
Example
Transition
201
Manual Transition
Automatic Transition
VTrak is Beeping
Troubleshooting
Front Panel
LEDs Display Amber or Red
VTrak M310p/M200p disk carrier LEDs
Drive Status Indicators
Back of Enclosure
Dark Green Amber Red
Fan LED on a VTrak M310p/M210p cooling unit
Green Amber Flashing
CLU Reports a Problem
PDM
WebPAM PROe Reports a Problem
211
Event Action
Battery
Event Notification Response
Battery reconditioning has
Controller
Blowers
Cache
Drive Interface Controller
Disk Array
Host Interface Controller
Enclosure
Event Log
Logical Drive
Media Patrol
PDM
Physical Disk
Physical disk negotiation
RAID Level Migration
PSU Fans
Rebuild
Spare Check
Redundancy Check
Resource
Stripe Level Migration
Spare Drives
Synchronization
Subsystem
System VTrak
Transition
Watermark
With a Hot Spare Drive
When a Disk Drive Fails
Critical & Offline Disk Arrays
Rebuild Operation
Without a Hot Spare Drive
230
Enclosure Problems
Overheating
Power Supplies
Termination
Connection Problems
Scsi Connections
Network Connections
Serial Connections
Amber Green Flashing Green
Unsaved Data in the Controller Cache
How can I tell when the VTrak has fully booted?
Frequently Asked Questions
Why does VTrak come with a Command Line Utility?
What kind of disk drives can I use with VTrak?
Are logical drives on VTrak limited to 2.199 terabytes?
Can VTrak run using just one power supply?
Technical Support Services
Contact Technical Support
How can I be sure everything is working OK on the VTrak?
Europe, Africa, Middle East
United States
Germany
Italy
China
Taiwan
Disclaimer of other warranties
Limited Warranty
Your Responsibilities
Returning Product For Repair
Or retailer
Pin Signal
Serial Connector Pinout
Load MIB Files
Snmp MIB Files
Index
212
PROe 25
PDM 30, 110, 144
RAID 5 183
Create 113, 155 delete 113
253
VTrak M310p, M210p Product Manual 254