Symbologies
Standard 2 of 5 — continued
Length Control
Fixed Length Decoding — When fixed length decoding is enabled, the scanner will decode a bar code if the label length matches one of the configurable fixed lengths.
Variable Length Decoding — When variable length decoding is enabled, the scanner will decode a bar code if the label length falls in the range of the configurable minimum and maximum length.
Configuring Fixed Length Decoding:
1.Scan the START bar code.
2.Scan the Fixed Length Decoding bar code.
3.Scan the END bar code.
4.Set Length 1 to the first fixed length by following the Standard 2 of
below.
5. Set Length 2 to the second fixed length (or to ‘00’ if there is only one fixed length) by following the Standard 2 of 5 Length 1, Length 2
below.
Configuring Variable Length Decoding:
1.Scan the START bar code.
2.Scan the Variable Length Decoding bar code.
3.Scan the END bar code.
4.Set Length 1 to the minimum length by following the Standard 2
below.
5. Set Length 2 to the maximum length by following the Standard 2 below.