Length 1, Length 2 Programming Instructions
Length 1, Length 2 Programming Instructions
Programming Instructions
PDF 417 Length 1, Length 2
Length 1, Length 2 Programming Instructions

Symbologies

PDF 417 — continued

Length Control

Fixed Length Decoding — When fixed length decoding is enabled, the scanner will decode a bar code if the label length matches one of the configurable fixed lengths.

Variable Length Decoding — When variable length decoding is enabled, the scanner will decode a bar code if the label length falls in the range of the configurable minimum and maximum length.

Configuring Fixed Length Decoding:

1.Scan the START bar code.

2.Scan the Fixed Length Decoding bar code.

3.Scan the END bar code.

4.Set Length 1 to the first fixed length by following the PDF 417

below.

5. Set Length 2 to the second fixed length (or to ‘0000’ if there is only one fixed length) by following the

below.

Configuring Variable Length Decoding:

1.Scan the START bar code.

2.Scan the Variable Length Decoding bar code.

3.Scan the END bar code.

4.Set Length 1 to the minimum length by following the PDF 417

below.

5. Set Length 2 to the maximum length by following the PDF 417 below.

5-88

PowerScan® 7000 Linear Imager

Page 180
Image 180
PSC 7000 manual Length Control