Interface Features
Wand Emulation
Supported Symbologies
The Wand Emulation interface will transmit bar code data as a wand device would. This interface will transmit the following bar code sym- bologies:
•UPC/EAN
•UPC/EAN with addons
•Code 39
•Full ASCII Code 39
•Interleaved 2 of 5
•Codabar
•Code 128
Pharmacode 39 is transmitted as Code 39, all other bar code symbology types read by the scanner will be transmitted as Code 128.
Wand Emulation Bar Code Format
The following format settings are required for the wand emulation inter- face. These settings have been
•
•
•
•
•Code 39, Code 39 Full ASCII, and Pharmacode 39 bar codes must NOT contain start / stop characters.
•Codabar bar codes must include the start / stop characters, pre- sented in the ABCD format.
•Interleaved 2 of 5 bar codes must have an even number of digits.