Overview
Users Guide 91Table A-4: Serial Programming Parameters

Code Parameter ID # Type Acceptable Input Predefined Default

(C8)

Enter 1 for On and 0 for Off.
Host select C0 Value 11 = ATs, PS/2s, and
compatibles
15 = IBM terminals
None
Baud rate C1 Value 00 = 300
01 = 600
02 = 1200
03 = 2400
04 = 4800
05 = 9600
06 = 19,200
07 = 38,400
08 = 76,800
05
Data bits C2 Value 07 = 7 bits
08 = 8 bits
08
Parity C3 Value 00 = None
03 = Odd
04 = Even
00
Stop bits C4 Value 01 = 1 bit
02 = 2 bits
01
Enable Xon/Xoff C5 On/Off On

or

Off Off
Linefeed (LF)

(Valid for CA = 00 only)

C6 Value 00 = None
01 = Strip LF
02 = Add LF
00
Predefined serial defaults C8
End-of-file character C9 Value Any single ASCII
character
1A
Protocol CA Value 00 = EOR only
01 = CR with checksum
and ACK/NAK response
02 = Xmodem
01
End-of-record (EOR) character CC Value Any single
ASCII character
(CR)
Timeout CD Value 0099

(100-millisecond units)

10