Table A-3: General Programming Parameters

Programming Parameters

Table A-3: General Programming Parameters

Code Parameter

ID #

Type

Acceptable Input

Predefined Defaults

D0

D1

D2

 

 

 

 

 

Code 39

 

 

 

Enter 1 for On and 0 for Off.

Enable

00

On/Off

On or Off

 

Off

On

On

 

 

 

 

 

 

 

 

Minimum length

01

Value

00–60

 

00

00

00

 

 

 

 

 

 

 

 

Maximum length

02

Value

00–60

 

00

60

20

 

 

 

 

 

 

 

 

Enable checksum

03

On/Off

On or Off

 

Off

Off

Off

 

 

 

 

 

 

 

 

Send checksum

04

On/Off

On or Off

 

Off

Off

Off

 

 

 

 

 

 

 

 

Full ASCII mode

05

On/Off

On or Off

 

Off

On

On

 

 

 

 

 

 

 

 

Accumulate mode

06

On/Off

On or Off

 

Off

On

Off

 

 

 

 

 

 

 

 

Enable AIAG alternate

07

On/Off

On or Off

 

Off

Off

Off

check digit

 

 

 

 

 

 

 

 

 

 

 

 

Interleaved 2 of 5

 

 

 

Enter 1 for On and 0 for Off.

Enable

08

On/Off

On or Off

 

Off

On

On

 

 

 

 

 

 

 

 

Minimum length

09

Value

02–60

 

02

02

06

 

 

 

 

 

 

 

 

Maximum length

0A

Value

02–60

 

02

60

10

 

 

 

 

 

 

 

 

Enable checksum

0B

On/Off

On or Off

 

Off

Off

Off

 

 

 

 

 

 

 

 

Send checksum

0C

On/Off

On or Off

 

Off

Off

Off

 

 

 

 

 

 

 

 

Use lengths 6 and 14 only

0D

On/Off

On or Off

 

Off

Off

Off

(case code)

 

 

 

 

 

 

 

 

 

 

 

 

Codabar

 

 

 

Enter 1 for On and 0 for Off.

Enable

20

On/Off

On or Off

 

Off

On

On

 

 

 

 

 

 

 

 

Minimum length

21

Value

00–60

 

00

02

04

 

 

 

 

 

 

 

 

Maximum length

22

Value

00–60

 

00

60

20

 

 

 

 

 

 

 

 

Send start/stop

23

On/Off

On or Off

 

Off

Off

Off

 

 

 

 

 

 

 

 

Convert Codabar to CLSI

24

On/Off

On or Off

 

Off

Off

Off

 

 

 

 

 

Code 93

 

 

 

Enter 1 for On and 0 for Off.

Enable

2C

On/Off

On or Off

 

Off

On

On

 

 

 

 

 

 

 

 

Minimum length

2D

Value

00–50

 

00

01

02

 

 

 

 

 

 

 

 

Maximum length

2E

Value

01–50

 

00

50

20

 

 

 

 

 

 

 

 