(minutes)

Programming Parameters

Code Parameter

 

ID #

 

Type

 

Acceptable Input

Predefined Defaults

 

 

 

D0

 

D1

 

D2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Other Controls

 

 

 

 

 

 

Enter 1 for On and 0 for Off.

Enable manual reset

 

B0

 

On/Off

 

On or Off

On

 

On

 

On

 

 

 

 

 

 

 

 

 

 

 

 

 

Auto-Off

 

B2

 

Value

 

 

00–99

00

 

60

 

10

 

 

 

 

 

 

(minutes)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Intercharacter delay (keyboard

 

B3

 

Value

 

 

00–99

00

 

06

 

00

wedge only)

 

 

 

 

 

(milliseconds)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Add symbology identifiers*

 

B5

 

On/Off

 

On or Off

Off

 

On

 

Off

Good-read tone

 

B8

 

Value

 

00 (low) – 07 (high)

05

 

05

 

05

 

 

 

 

 

 

 

 

 

 

 

 

 

Good-read number of beeps

 

B9

 

Value

 

 

01–04

01

 

01

 

01

 

 

 

 

 

 

 

 

 

 

 

 

Good-read tone duration

 

BA

 

Value

 

00 = 0.14 sec.

01

 

01

 

01

 

 

 

 

 

 

01 = 0.07 sec.

 

 

 

 

 

 

 

 

 

 

 

02 = 0.45 sec.

 

 

 

 

 

 

 

 

 

 

 

03 = 0.22 sec.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Beeper volume

 

BC

 

Value

 

 

00 = Off

07

 

07

 

07

 

 

 

 

 

 

01 (low) – 07 (high)

 

 

 

 

 

 

 

 

 

 

 

08 = One level higher

 

 

 

 

 

 

 

 

 

 

 

09 = One level lower

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Error tone

 

BD

 

Value

 

00 (low) – 07 (high)

03

 

03

 

03

 

 

 

 

 

 

 

 

 

 

 

 

Time format

 

D8

 

On/Off

 

On = 24-hour

On

 

On

 

On

 

 

 

 

 

 

Off = 12-hour

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Date format

 

D9

 

On/Off

 

On = International

Off

 

Off

 

Off

 

 

 

 

 

 

Off = U.S.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Keyboard click

 

DD

 

On/Off

 

On or Off

On

 

On

 

On

 

 

 

 

 

 

 

 

 

 

 

 

 

Laser delay

 

DE

 

Value

 

 

00–99

01

 

01

 

01

 

 

 

 

 

 

(10-millisecond units)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

*

A

= UPC-A

 

 

E

= UPC-E

K

= Code 128

 

 

B

= Interleaved 2 of 5

G

= EAN-8

L

= Code 93

 

 

C

= Code 39

I

= Codabar

M

= EAN-13

 

*.

 

 

 

 

 

 

 

 

 

 

 

 

90

PT2000™ & TopGun™

Page 100
Image 100
PSC PT2000 & TopGun, Programming Parameters, Enter 1 for On and 0 for Off, minutes, milliseconds, millisecond units