4–Configuration
Configuring Fibre Channel Array Hosts and LUN Assignments
ISR651101-00 J 4-15

When assigning LUNs to your VPG host entities, do not assign the same LUN to

two VPG host entities. Figure 4-12 shows a valid LUN presentation. Each LUN is

presented to only one VPG. Any of these LUNs can be presented to any number

of other Fibre Channel hosts on the array, but can be presented to one and only

one VPG of the iSR6200.

Figure 4-12. Correctly Assigning LUNs to Your VPG Host Entities
iSR6200
Storage Array
Blade 1
21:00:00:c0:dd:13:16:f8
21:01:00:c0:dd:13:16:f8
21:02:00:c0:dd:13:16:f8
21:00:00:c0:dd:13:16:f8
21:00:00:c0:dd:13:16:f9
FC1
FC2
Host Entities
Host Entity 0
21:01:00:c0:dd:13:16:f8
21:01:00:c0:dd:13:16:f9
Host Entity 1
21:02:00:c0:dd:13:16:f8
21:02:00:c0:dd:13:16:f9
Host Entity 2
21:00:00:c0:dd:13:16:f9
21:01:00:c0:dd:13:16:f9
21:02:00:c0:dd:13:16:f9
LUN 1
LUN 2
LUN 3
LUN 4