A – Specifications
Switch Dimensions
59042-00 A A-3
A.4
Switch DimensionsA.5
Switch ElectricalA.6
Switch EnvironmentalWidth....................................... ........
Height ....................................... ......
Depth..... ................................. ........
8.5”
1.70”
20.0”
Weight....................................... ...... 8.5 lbs.
Operating voltage ........................... 90 to 137 Vac; 47 to 63 Hz
180 to 264 Vac; 47 to 63 Hz
Power source loading..................... 1.0 Amps maximum at 90 to 137 Vac
0.45 Amps maximum at 180 to 264 Vac
Heat Output (maximum) 70 watts
Circuit Protection ........................... . Internally fused
Temperature
■Operating...... ............................
■Non-operating........................... 5 to 50°C (41 to 122°F)
-40 to 65°C (-40 to 149°F)
Humidity
■Operating...... ............................
■Non-operating........................... 15% to 80%, non-condensing
25% to 90%, non-condensing
Altitude
■Operating...... ............................
■Non-operating........................... 0 to 3048m (0 to 10,000 feet)
0 to 15,240m (0 to 50,000 feet)
Vibration
■Operating...... ............................
■Non-operating...........................
IEC 68-2
5-500 Hz, random, 0.21 G rms, 10 minutes
5-500 Hz, random, 2.09 G rms, 10 minutes
Shock
■Operating...... ............................
■Non-operating...........................
IEC 68-2
4 g, 11ms, 20 repetitions
30g, 292 ips, 3 repetitions, 3 axis
Air flow............................................ Front-to-back or back-to-front, by model