The accompanying diagram (Picture 7-2), along with your alarm’s manual should be consulted to ensure proper connection.

Normal open or Normal close type

Parallel connect COM end and GND end of the alarm detector (Provide external power to the alarm detector).

Parallel connect the Ground of the combo DVR and the ground of the alarm detector.

Connect the NC port of the alarm sensor to the combo DVR alarm input(ALARM)

Use the same ground with that of combo DVR if you use external power to the alarm device.

Alarm input public end should jump out with device power end. Alarm Device Connection Terminal

+12V GND COM PC

Alarm Device

Connection Terminal

ALARM

GND

+12V GND

PICTURE 7-2

7.2 ALARM OUTPUT

The alarm output port should not be directly connected to a higher power load (greater than 1A) to avoid high current which may damage the relay. Use the co-contactor to establish the connection between the alarm output port and the load.

2 way relay alarm output (NO contact). Provides external power to external alarm device.

To avoid overloading, please read the following relay parameters sheet carefully.

RS485 A/B cable is for the A/B cable of the PTZ camera.

 

Relay Specification

 

 

 

 

 

 

 

 

 

 

Model:

JRC-27F

 

 

 

 

 

 

 

 

 

 

Material of the contact

Silver

 

 

 

 

 

 

 

 

 

 

Rating (Resistance Load)

Rated switch capacity

30VDC 2A, 125VAC 1A

 

 

 

 

 

 

 

 

 

 

Maximum switch power

125VA 160W

 

 

 

 

 

 

 

 

 

 

Maximum switch voltage

250VAC, 220VDC

 

 

 

 

 

 

 

 

 

 

Maximum switch currency

1A

 

 

 

 

 

 

 

 

 

Insulation

Between contacts with same polarity

1000VAC 1minute

 

 

 

 

Between contacts with different

1000VAC 1minute

 

CHAPTER7

 

 

 

 

 

 

polarity

 

 

 

 

 

 

 

 

 

 

 

Between contacts and winding

1000VAC 1minute

 

 

 

 

ALARMS

 

 

 

 

Surge voltage

Between contacts with same polarity

1500V (10×160us)

 

 

 

 

 

 

 

 

 

 

Length of open time

3ms max

 

 

 

 

 

 

 

 

 

 

Length of close time

3ms max

 

 

 

 

 

 

 

 

 

 

Longevity

Mechanical

50×106 times (3Hz)

 

 

 

 

 

 

 

 

 

 

Electrical

200×103 times (0.5Hz)

 

 

 

 

 

 

 

 

 

Temperature

-40°C ~+70°C (-40°F to +158°F)

 

 

 

 

 

 

 

 

 

 

56

57

Page 29
Image 29