SPECIFICATIONS- PowerLight 6.0 II Electrical Data
QSControl Control and Monitor Parameters on/standby, channel gain, mute, polarity, input level, output level, heat sink temperature, output load sense, clip detect, protect detect, operating Mode sense (Stereo/Parallel/Bridge)
Cooling | four continuously variable speed fans, rear to front airflow |
Amplifier Protection | short circuit, open circuit, thermal, ultrasonic, and RF protection |
| stable into reactive or mismatched loads |
Load Protection | |
Weight | 53 lbs (net), 60 lbs (shipping) |
Power Requirements | 120 Volts AC, 50 to 60 Hertz, 30 Amp NEMA |
| OR |
| 240 Volts AC, 50 to 60 Hertz, 15 Amp service |
Current Consumption | 120 Volts |
(in amperes, rms) |
|
240 Volts ![](/images/new-backgrounds/19952/1995249xi2.webp)
Current Consumption Notes: | Typical- 1/8 power, pink noise, represents typical program with occasional clipping |
| Full- 1/3 power, pink noise, represents severe program with heavy clipping |
| Maximum- continuous sine wave at 1% clipping |
| Note: Specifications are subject to change without notice. |
APPENDIX-
DataPort Pinout
The DataPort connection is
Pin | Signal Description |
1Ch. 1 Minus
2AC Standby Control
3V- MON Ch. 1 and Subcode 1
4I- MON Ch. 1 and Subcode 2
5Clip/Protect Ch. 1
6Hard Ground
7Ch. 1 Plus (+) Input Signal
8Ch. 2 Plus (+) Input Signal
9+15V from Amplifier
10Data Reference Ground
11Ch. 2 Minus
12Amplifier IDR (Model ID)
13V- MON Ch. 2 and Subcode 3
14I- MON Ch. 2 and Subcode 4
15Clip/Protect Ch. 2