5 Fireplace Size Requirements

A. Minimum Fireplace Opening

Minimum fireplace opening requirements for a standard 3/4 inch deep surround are shown in Figure 5.1. For smaller openings, an optional 1-1/2 inch deep surround is available and dimensions are shown in Figure 5.2.

WARNING! Risk of Fire or Burns! Provide adequate clearance around air openings and for service access.

Due to high temperatures, the appliance should be locat- ed out of traffic and away from furniture and draperies.

The firebrick (refractory), glass doors, screen rails, screen mesh and log grates can be removed from a factory built fi rebox in order to gain minimum gas insert opening requirements.

Any smoke shelves, shields and baffles may be removed

from the factory built fi rebox if attached with mechanical fasteners.

The metal floor of the solid fuel firebox may be removed to facilitate the installation of the insert. The appliance may not be placed directly on the base of the outer wrap, a 1/4 inch airspace must be provided between the insert and the floor of the outer wrap. Use the levelling legs to raise the insert a minimum of 1/4 inch. The original fi replace may never be returned to solid fuel in this condition. The sidewalls and top structure of the fi rebox may not be altered with the exception of removable baffles and dampers.

Cutting of any sheet metal parts of the fi replace in which the gas fi replace insert is to be installed is prohibited, except the fl oor as tested for and as noted above.

TOP VIEW

 

FRONT VIEW

 

 

C

A

 

 

G

E

I

 

 

H

 

 

B

 

 

D

SIDE VIEW

F

MINIMUM FIREPLACE SIZE

 

Location

QFI35

 

 

QFI30

 

 

 

 

 

 

 

 

Inches

 

Millimeters

Inches

 

Millimeters

 

 

 

 

 

 

 

 

 

 

 

 

A

Rear Width

23-1/2

 

597

20-1/4

 

514

 

 

 

 

 

 

 

 

B

Front Width

34-5/8

 

879

30-1/2

 

775

 

 

 

 

 

 

 

 

C

Glass Opening Width

31-9/16

 

802

27-7/16

 

697

 

 

 

 

 

 

 

 

D

Glass Opening Height

15-11/16

 

398

12-13/16

 

325

 

 

 

 

 

 

 

 

E

Height-Front

24

 

610

20-1/2

 

521

 

 

 

 

 

 

 

 

F

Height-Rear

21-1/16

 

535

17-5/8

 

448

 

 

 

 

 

 

 

 

G**

Unit Depth

16

 

406

14-3/4

 

375

 

 

 

 

 

 

 

 

H

Venting Depth

10-1/2

 

267

9-1/2

 

241

 

 

 

 

 

 

 

 

I

Height to Top of

22

 

559

18-1/4

 

464

Glass Frame

 

 

 

 

 

 

 

 

 

*Note: If exhaust collar on insert and fi replace damper do not line up, add 4 inches (102 mm) to minimum

replace height for bends in vent pipe.

**Unit depth is measured to the back of the surround to give the depth needed for installation.

In addition to these dimensions, also reference Clearances and Mantel Projections (Section 5.B).

Figure 5.1 Fireplace Opening

Quadra-Fire • QFI30, QFI35 • 2227-900 Rev. H • 1/11

17

Page 17
Image 17
Quadra-Fire QF130 owner manual Fireplace Size Requirements, Minimum Fireplace Opening, Minimum Fireplace Size, QFI35 QFI30