CUT AND BEND

FLASHING AS NEEDED

TO FIT CHIMNEY

SEALANT

ADHESIVE

Figure 8.2

Trim chimney top plate to minimize excess overhang or bend over fl ue tile (see Figure 8.2).

Place 3/8 inch bead of 300º F silicone on fl ue tile top.

D.Placing, Securing and Leveling the Appli- ance

Install insert (without surround attached) into existing fi replace while pulling collar slide plate forward.

Install gas line into hole provided on insert side.

If applicable install remote control wires into insert side (see Section 8.E).

Secure collar slide plate to appliance by placing locking handle into position with locking tabs (see Figure 8.1) and secure with #8 screw.

Level the appliance from side to side and front to back. If necessary, use the leveling legs included with the manual bag to set each corner of the base.

Position any excess flexible vent pipe back up into chimney without sagging. Twist and push flex vent together to shorten.

Install fiberglass insulation pieces to back face of surround.

Attach surround. Follow instructions for surround installation included with the front.

Push insert into the opening so that it tightly overlaps the fi replace opening.

WARNING! Risk of Fire! Only an approved Hearth & Home Technologies surround may be used to cover inte- gral grills on solid fuel burning fireplaces. No other com- ponents such as shrouds, sheetmetal plates, etc., may be used to seal off vents.

WARNING! Risk of Explosion! Failure to position the parts in accordance with these diagrams or failure to use only parts specifically approved with this appliance may result in property damage or personal injury.

WARNING! Risk of Explosion/Combustion Fumes! Connect vent sections per installation instructions.

Connect exhaust vent pipe ONLY to exhaust starting collar and termination cap center collar.

Connect inlet air vent ONLY to inlet air collar on appliance and the termination cap inlet air collar.

DO NOT allow vent to sag below connection point to appliance.

E. Remote Control

IPI Models:

If a remote control kit is used to control blower function, the Auxiliary 300 module can only be placed in the control cavity to the right of the control panel. See Figure 8.3.

AUXILIARY 300 MODULE

Figure 8.3 Location of AUX300 for Remote Control Blower Function - IPI

22

Quadra-Fire • QFI30, QFI35 • 2227-900 Rev. H • 1/11

Page 22
Image 22
Quadra-Fire QF130 owner manual Placing, Securing and Leveling the Appli- ance, IPI Models