Quadra-Fire QF130 owner manual D. Fan Wiring with Remote, E.Control Module Operation

Models: QF130

1 41
Download 41 pages 40.52 Kb
Page 27
Image 27
D. Fan Wiring with Remote

D. Fan Wiring with Remote

This appliance may be used with an RC200 or RC300 remote control. See Figure 10.3.

1.Remove cord assembly spades from rheostat and sensor switch.

NOTICE: Fan speed and operation are controlled by the remote control. The sensor switch and rheostat are no longer needed.

2.Plug two cord assembly spade connectors together.

3.Unplug fan cord assembly from standard cord assembly.

4.Plug fan cord assembly into AUX300 module.

5.Plug AUX300 module into the standard cord assembly.

E.Control Module Operation

See Section 2.H for control module operation instructions.

NOTE: IF ANY OF THE ORIGINAL WIRE AS SUPPLIED WITH THE APPLIANCE MUST BE REPLACED, IT MUST BE REPLACED WITH TYPE 1050 C RATED WIRE.

NOTE: USE ZIP TIES TO RESTRAIN THE LOOSE WIRES UNDERNEATH THE APPLIANCE AND KEEP THEM AWAY FROM THE BLOWER WHEEL (FAN BLADES).

BLOWER

PLUG

 

120V EXISTING

STEP 5

 

OUTLET

 

STEPS

 

1 & 2

 

STEPS

 

3 & 4

 

SENSOR SWITCH

WHT (2)

 

GRN (2)

 

BLK (2)

 

BLK (2)

SPEED CONTROL

GRN (2)

(RHEOSTAT)

BLK (2)

 

NOTE: SENSOR SWITCH AND RHEOSTAT SPEED CONTROL MUST BE REMOVED FROM CIRCUIT IF SYSTEM IS CONTROLLED WITH RC200/RC300 REMOTE.

PLUG INTO 120V

EXISTING OUTLET

DC REGULATOR

RECEPTICLE

TO CONTROL

MODULE

BLK E.Control Module Operation

BLKManual background

BLOWER RECEPTICLE

AUX 300 MODULE

FAN

WHT

GRN

BLK

BLK

GRN

WHT

BLK

GRN

BLK

BLOWERS

BLKManual background

GRN

BLK

Figure 10.3 Wiring Diagram - Fan with RC200/RC300 Remote

Quadra-Fire • QFI30, QFI35 • 2227-900 Rev. H • 1/11

27

Page 27
Image 27
Quadra-Fire QF130 owner manual D. Fan Wiring with Remote, E.Control Module Operation