Quadra-Fire QV36DC-A Installing the Vent System, Identifying Vent Components, Terminations Kits

Models: QV36DC-A

1 36
Download 36 pages 62.39 Kb
Page 11
Image 11
Step 3. Installing the Vent System

Step 3. Installing the Vent System

A. Vent System Approvals

This model is approved to use DVP-series direct vent pipe components and terminations (see Figures 4 and 5). Approved vent system components are labeled for identifi- cation. This pipe is tested and listed as an approved com- ponent of the fireplace. The pipe is tested to be run inside an enclosed wall. There is no requirement for inspection openings at each joint within the wall. There is no required pitch for horizontal vent runs. NO OTHER VENTING SYS-

TEMS OR COMPONENTS MAY BE USED.

Detailed installation instructions are included with each vent termination kit and should be used in conjunction with this Owner’s Manual. The flame and ember appearance may vary based on the type of fuel burned and the venting configuration used.

Identifying Vent Components

The vent systems installed on this gas fireplace may include one, two, or three 90° elbow assemblies. The relationships of vertical rise to horizontal run in vent configurations using 90° elbows MUST BE strictly adhered to. The rise to run relationships are shown in the venting drawings and tables. Refer to the diagrams on the next several pages.

NOTE: Two 45° elbows may be used in place of one 90° elbow. Rise to run ratios in the vent system must be fol- lowed if 45° elbows are used.

This model has vent starting collars on both the top and the back of the unit. Depending upon the installation, decide which ONE set of starting collars will be used to attach the vent system. The starting collar sealing cap must remain on the starting collar NOT used.

VERTICAL A. Vent System Approvals

TERMINATION

HORIZONTAL

TERMINATION

WALL FIRESTOPTEMS OR COMPONENTS MAY BE USED.

90 DEGREE ELBOW

Terminations Kits

(Required to have a minimum of 3 feet of vertical in the vent system)

DVP-TRAP SERIES

DVP-TVHW

DVP-TB1

STORM COLLAR

Identifying Vent Components ROOF FLASHING

PIPE LENGTH

CEILING

FIRESTOP

Figure 5. Vent System Components and Termination Kits

14

Quadra-FireQV36DC-A2161-900 Rev. C • 6/09

Page 11
Image 11
Quadra-Fire QV36DC-A Installing the Vent System, Identifying Vent Components, A. Vent System Approvals, Terminations Kits