Step 3. Installing the Vent System
A. Vent System Approvals
This model is approved to use
TEMS OR COMPONENTS MAY BE USED.
Detailed installation instructions are included with each vent termination kit and should be used in conjunction with this Owner’s Manual. The flame and ember appearance may vary based on the type of fuel burned and the venting configuration used.
Identifying Vent Components
The vent systems installed on this gas fireplace may include one, two, or three 90° elbow assemblies. The relationships of vertical rise to horizontal run in vent configurations using 90° elbows MUST BE strictly adhered to. The rise to run relationships are shown in the venting drawings and tables. Refer to the diagrams on the next several pages.
NOTE: Two 45° elbows may be used in place of one 90° elbow. Rise to run ratios in the vent system must be fol- lowed if 45° elbows are used.
This model has vent starting collars on both the top and the back of the unit. Depending upon the installation, decide which ONE set of starting collars will be used to attach the vent system. The starting collar sealing cap must remain on the starting collar NOT used.
VERTICAL
TERMINATION
HORIZONTAL
TERMINATION
WALL FIRESTOP
90 DEGREE ELBOW
Terminations Kits
(Required to have a minimum of 3 feet of vertical in the vent system)
STORM COLLAR
ROOF FLASHING
PIPE LENGTH
CEILING
FIRESTOP
Figure 5. Vent System Components and Termination Kits
14 |