Quadra-Fire QV36DC-A Step, Wiring the Fireplace, Optional Accessories, Appliance Requirements

Models: QV36DC-A

1 36
Download 36 pages 62.39 Kb
Page 26
Image 26
Step 8.

 

3/16” PIGGYBACK CONNECTOR

 

 

REMOTE SWITCH

 

 

BLACK S2

PIGTAIL

 

 

 

ON

 

 

 

 

OFF

 

 

 

WHITE T2

ON/OFF

 

 

 

SWITCH

 

 

GAS VALVE

RED T1

 

 

 

 

 

 

 

 

THERMOPILE

 

THERMOCOUPLE

 

BLACK S1

OPTIONAL WALL SWITCH,

 

 

 

 

 

 

 

 

THERMOSTAT OR REMOTE

Figure 34. Standing Pilot Ignition Wiring Diagram

 

 

 

Step 8.

Wiring the Fireplace

 

Optional Accessories

 

NOTE: Electrical wiring must be installed by a licensed electrician.

CAUTION: DISCONNECT REMOTE CONTROLS IF ABSENT FOR EXTENDED TIME PERIODS. THIS WILL PREVENT ACCIDENTAL FIREPLACE OPERATION.

Appliance Requirements

This appliance DOES NOT require 110-120 VAC to operate.

A 110-120 VAC circuit for this product must be protected with ground-fault circuit-interrupter protection, in compli- ance with the applicable electrical codes, when it is in- stalled in locations such as in bathrooms or near sinks.

!WARNING: DO NOT CONNECT 110-120

VAC TO THE GAS CONTROL VALVE OR THE APPLIANCE WILL MALFUNCTION AND THE VALVE WILL BE DESTROYED.

Optional fan and remote control kits require that 110-120 VAC be wired to the factory installed junction box before the fireplace is permanently installed.

Wall Switch

Position the wall switch in the desired position on a wall. Run a maximum of 25 feet (7.8 m) or less length of 18 A.W.G. minimum wire and connect it to the fireplace ON/ OFF switch pigtails

!WARNING: DO NOT CONNECT 110-120

VAC TO THE WALL SWITCH OR THE CON- TROL VALVE WILL BE DESTROYED.

CAUTION: LABEL ALL WIRES PRIOR TO DISCONNEC- TION WHEN SERVICING CONTROLS. WIRING ERRORS CAN CAUSE IMPROPER AND DANGEROUS OPERA- TION. VERIFY PROPER OPERATION AFTER SERVICING.

 

VARIABLE SPEED CONTROL

NOTE: IF ANY OF THE ORIGINAL WIRE

 

 

 

 

AS SUPPLIED WITH THE APPLIANCE

 

 

 

 

MUST BE REPLACED, IT MUST BE

 

BLK

BLK

 

REPLACED WITH TYPE 105° C RATED WIRE.

 

JUNCTION BOX

 

 

 

 

 

BLK

BLK

 

BLOWER RECEPTACLE

 

 

 

 

 

 

 

BLK

 

BLK

 

 

 

 

 

 

BLK

 

 

 

BLK

WHT

WHT

 

 

GROUND

 

 

TEMPERATURE

 

 

 

 

 

 

 

SENSOR SWITCH

 

 

BLOWER

 

 

 

 

 

 

BLK

GRN

WHT

 

 

 

 

 

 

 

BLOWER

SENSOR

 

 

 

 

SWITCH

 

 

110-120 VAC

 

 

“FAN”

RECEPTACLE SPEED Wiring the Fireplace CONTROL

Quadra-FireQV36DC-A2161-900 Rev. C • 6/09