Quadra-Fire QV36DC-A VENTING WITH THREE 3 90 ELBOWS, V Ft, H + H1, Venting with three 90 elbows

Models: QV36DC-A

1 36
Download 36 pages 62.39 Kb
Page 17
Image 17
V (FT.)

VENTING WITH THREE (3) 90° ELBOWS

 

H1

 

 

 

V1

 

 

V

 

 

H

V (FT.)

 

H (FT.)

1’ MIN. (305mm)

5’ MAX. (1.52m)

2’ MIN. (610mm)

10’ MAX. (3.1m)

3’ MIN. (914mm)

15’ MAX. (4.65m)

4’ MIN. (1.22m)

20’ MAX. (6.2m)

NOTE: H + H1 = 20’ MAX. (6.2m)

 

V + V1 + H + H1= 40’ MAX. (12.4m)

V1

 

 

 

H1

V

 

 

 

 

H

V (FT.)

H + H1

(FT.)

1’ MIN. (305mm)

5’ MAX. (1.52m)

2’ MIN. (610mm)

10’ MAX. (3.1m)

3’ MIN. (914mm)

15’ MAX. (4.65m)

4’ MIN. (1.22m)

20’ MAX. (6.2m)

H +H1 = 20’ MAX. (6.2m)

 

NOTE: V+V1+H +H1 = 40’ MAX. (12.4m)