A.5

 

 

With proper installation, operation, and maintenance your gas fireplace will

 

 

 

 

provide years of trouble-free service. If you do experience a problem, this

 

 

 

 

troubleshooting guide will assist a qualified service person in the diagnosis

 

 

 

 

of a problem and the corrective action to be taken. This troubleshooting

 

 

Troubleshooting

guide can only be used by a qualified service technician.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Standing Pilot Ignition System

 

 

 

 

 

 

 

 

 

Symptom

 

Possible Causes

Corrective Action

 

 

 

 

 

 

 

1. After repeated triggering

a. Defective ignitor.

 

Check the spark at the electrode and pilot. If no spark and electrode

 

of the red or black piezo

 

 

wire is properly connected, replace the ignitor.

 

ignitor button, the spark

 

 

 

 

b. Defective pilot or misaligned

Using match, light the pilot. If the pilot lights, turn off the pilot and

 

ignitor will not light the pilot.

 

 

 

 

electrode (spark at electrode).

trigger the red piezo ignitor button again. If the pilot lights, an im-

 

 

 

 

 

 

proper gas/air mixture caused the bad lighting and a longer purge

 

 

 

 

 

 

period is recommended. If the pilot will not light, ensure the gap

 

 

 

 

 

 

at the electrode and pilot is one-eighth (1/8) inch to have a strong

 

 

 

 

 

 

spark. If the gap is OK, replace the pilot.

 

 

 

 

 

 

 

 

 

 

c. No gas or low gas pressure.

Check the remote shut-off valves from the fireplace. Usually, there

 

 

 

 

 

 

is a valve near the gas main. There can be more than one (1) valve

 

 

 

 

 

 

between the fireplace and the main.

 

 

 

 

 

 

 

 

 

 

 

d. No LP in tank.

 

Check the LP (propane) tank. You may be out of fuel.

 

 

 

 

 

 

2. The pilot will not stay lit

a. Defective thermocouple.

Check that the pilot flame impinges on the thermocouple. Clean

 

after carefully following the

 

 

and/or adjust the pilot for maximum flame impingement.

 

lighting instructions.

 

 

 

Ensure that the thermocouple connection at the gas valve is fully

 

 

 

 

 

 

 

 

 

 

 

 

inserted and tight (hand tighten plus 1/4 turn).

 

 

 

 

 

 

Disconnect the thermocouple from the valve, place one millivolt

 

 

 

 

 

 

meter lead wire on the tip of the thermcouple and the other meter

 

 

 

 

 

 

lead wire on the thermocouple copper lead. Start the pilot and hold

 

 

 

 

 

 

the valve knob in. If the millivolt reading is less than 15mV, replace

 

 

 

 

 

 

the thermocouple.

 

 

 

 

 

 

 

 

 

 

 

b. Defective valve.

 

If the thermocouple is producing more than 15 millivolts, replace

 

 

 

 

 

 

faulty valve.

 

 

 

 

 

 

3. The pilot is burning,

a. ON/OFF switch or wires

Check the ON/OFF switch and wires for proper connections. Place

 

there is no burner flame,

defective.

 

the jumper wires across the terminals at the switch. If the burner

 

the valve knob is in the ON

 

 

comes on, replace the defective switch. If the switch is OK, place the

 

position, and the ON/OFF

 

 

jumper wires across the switch wires at the gas valve. If the burner

 

switch is in the ON position.

 

 

comes on, the wires are faulty or connections are bad.

 

 

 

 

 

 

 

 

 

 

b. Thermopile may not be gener-

If the pilot flame is not close enough physically to the thermopile,

 

 

 

 

ating sufficient millivoltage.

adjust the pilot flame.

 

 

 

 

 

 

Be sure the wire connections from the thermopile at the gas valve

 

 

 

 

 

 

terminals are tight and that the thermopile is fully inserted into the

 

 

 

 

 

 

pilot bracket.

 

 

 

 

 

 

Check the thermopile with a millivolt meter. Take the reading at

 

 

 

 

 

 

TH-TP&TP terminals of the gas valve. The meter should read 325

 

 

 

 

 

 

millivolts minimum, while holding the valve knob depressed in the

 

 

 

 

 

 

pilot position, with the pilot lit, and the ON/OFF switch in the OFF

 

 

 

 

 

 

position. Replace the faulty thermopile if the reading is below the

 

 

 

 

 

 

specified minimum.

 

 

 

 

 

 

With the pilot in the ON position, disconnect the thermopile leads

 

 

 

 

 

 

from the valve. Take a reading at the thermopile leads. The read-

 

 

 

 

 

 

ing should be 325 millivolts minimum. Replace the thermopile if the

 

 

 

 

 

 

reading is below the minimum.

 

 

 

 

 

 

 

 

Quadra-FireQV36DC-A2161-900 Rev. C • 6/09

35

Page 32
Image 32
Quadra-Fire QV36DC-A owner manual Standing Pilot Ignition System, Symptom Possible Causes Corrective Action

QV36DC-A specifications

The Quadra-Fire QV36DC-A is a remarkable addition to the world of home heating, exemplifying innovation and efficiency in gas-burning fireplace inserts. Designed for those who seek both aesthetics and functionality in their living spaces, this model offers an impressive blend of features and technologies that enhance not only warmth but also the overall ambiance of any room.

One of the standout characteristics of the QV36DC-A is its direct vent design. This technology allows for a safe and efficient venting system that draws outside air for combustion, ensuring that indoor air quality is maintained. This feature eliminates the need for a traditional chimney, making it an ideal choice for modern homes or those with limited space. The direct vent capability also contributes to a higher efficiency rating, making it more cost-effective and environmentally friendly.

Another key feature of this model is its large viewing area, which is framed by a sleek and stylish surround. The expansive glass front provides a stunning visual display of the flames, creating a warm and inviting atmosphere. The QV36DC-A also comes with a range of decorative options, including various finish choices and customizable log sets, allowing homeowners to tailor the look of their fireplace to suit their personal style.

The QV36DC-A is equipped with advanced heating technologies, including a powerful heating capacity of up to 30,000 BTUs. This ensures that it can effectively heat larger spaces while maintaining a comfortable environment. The unit features adjustable fan speeds and a variable flame control system, allowing users to manipulate the level of heat and ambiance according to their preferences.

Additionally, the Quadra-Fire QV36DC-A is designed for ease of use and maintenance. The included remote control makes it convenient to adjust settings from a distance, while the self-cleaning glass door reduces the frequency of maintenance chores. The durable construction and high-quality materials ensure longevity, making it a wise investment for homeowners.

With its blend of functionality, efficiency, and beauty, the Quadra-Fire QV36DC-A stands as a premier choice for anyone looking to enhance their living space with the warmth and comfort of a gas fireplace insert. Its thoughtful design and advanced features make it not just a source of heat, but a centerpiece that elevates the overall ambiance of any home.