F. Horizontal Termination

Type A - Up and Out Installation

WARNING

Fire Risk.

Exhaust Fume Risk.

90° Elbow

Center Line

Pipe Length

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Termination Cap

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Pipe Length

 

 

 

 

Wall Thimble/

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Heat Shield

Wall Thimble Cover

 

 

 

 

 

 

 

 

 

 

 

 

Impaired Performance of Appliance.

Ensure vent components are locked together correctly.

Pipe may separate if not properly joined.

Step 2.

Direct vent pipe is designed with a locking connection. To connect the venting system to the appliance flue outlet, a twist-lock adapter is built into the appliance at the factory. Wall thickness may vary. Remember to include wall thickness in minimum clearances when figuring venting lengths for your installation needs.

Type B - Straight Out Installation

Snorkel Kit

Note: Female ends of direct vent pipe/elbows are designed to slide straight onto the male ends of adjacent pipes by orienting the pipe indentations so they match and slide into the entry slots on the male ends, see Figure 5.5. Push the pipe sections completely together, then twist-lock

Center Line

Wall Thimble 15-5/8 in.

Cover (397mm)

Pipe Length Minimum 6 in. (152mm) of pipe through wall

21 in. (533mm)

Wall Thimble or Heat Shield

Wall Strap 14 in. (356mm) Wide

one section clockwise approximately one-quarter turn, until the two sections are fully locked. The female locking lugs may not be visible from the outside. They may be located by examining the inside of the female ends.

Female Locking Lugs

Type C - 45° Elbow in Corner Installation

 

Wall Thimble/Heat Shield

45° Elbow

3 in. (76mm)

 

 

Clearance from

 

appliance corner to

 

combustible wall

3 in. (76mm) Clearance from appliance corner to combustible wall

Figure 5.4

Step 1.

Determine the desired location of the appliance. Check to ensure that wall studs or roof rafters are not in the way when the venting system is attached. If this is the case, you may want to adjust the location of the appliance.

Male Locking Lugs

Figure 5.5

WARNING

Fire Risk. Explosion Risk. Combustion Fume Risk.

Use vent run supports per installation instructions. Connect vent sections per installation instructions.

Maintain all clearances to combustibles.

Do NOT allow vent to sag below connection point to appliance.

Maintain specified slope (if required).

Improper support may allow vent to sag or separate.

12

Quadra-Fire • Sapphire • 7055-116 Rev. D • 6/11

Page 12
Image 12
Quadra-Fire SAPPHIRE-MBK Horizontal Termination, Type a Up and Out Installation, Type B Straight Out Installation, Step

SAPPHIRE-D-CSB, SAPPHIRE-D-PMH, SAPPHIRE-MBK, SAPPHIRE-D-MBK specifications

The Quadra-Fire Sapphire series of fireplaces, which includes the Sapphire-D-PMH, Sapphire-D-CSB, Sapphire-D-MBK, and Sapphire-MBK models, epitomizes modern heating technology combined with elegant design. These units are meticulously engineered to enhance both efficiency and aesthetics, making them perfect additions to contemporary living spaces.

One of the standout features of the Sapphire series is its advanced combustion technology. The fireplaces utilize a patented Clean Burn technology. This innovation ensures that the combustion process is as efficient as possible, resulting in reduced emissions and maximizing heat output. With lower particulate emissions, these models not only provide warmth but do so in an environmentally conscious manner.

In terms of performance, the Sapphire fireplaces are designed to deliver consistent and radiant heat. With their powerful heating capabilities, they can warm up large areas, making them suitable for homes of various sizes. The efficient design helps to distribute heat evenly throughout a room, eliminating cold spots and ensuring comfort in all corners of your living space.

The design aesthetics of the Sapphire series is equally impressive. The models feature a sleek, modern design complemented by a large viewing area, allowing for an unobstructed view of the mesmerizing flames. The glass is designed to remain clean for longer periods, thanks to the sophisticated airflow management system that directs air over the glass surfaces, reducing soot buildup.

Customization options are another notable characteristic of the Sapphire series. Homeowners can choose from various finishes and styles to match their home’s decor. The units are available in both traditional and contemporary designs, allowing for versatility in different architectural settings.

The Sapphire-D-PMH model is equipped with a programmable thermostat for added convenience and efficiency. This technology allows users to set the desired temperature, ensuring that their space remains comfortable without unnecessary manual adjustments.

On the other hand, the Sapphire-D-CSB model features an innovative fuel management system that optimally uses wood fuel for extended burn times. This means less frequent refueling and more time spent enjoying the warmth and ambiance the fireplace provides.

The Sapphire-D-MBK and Sapphire-MBK models are designed with durability and longevity in mind. Each unit is constructed from high-quality materials that are built to withstand extreme temperatures while maintaining structural integrity over time.

In summary, the Quadra-Fire Sapphire series combines advanced technology, unique design, and high efficiency. With features like Clean Burn technology, customizable options, and smart fuel management systems, the Sapphire fireplaces offer not just heat, but a stylish centerpiece for modern homes.