Quadra-Fire SAPPHIRE-D-PMH, SAPPHIRE-MBK, SAPPHIRE-D-MBK owner manual High Altitude Installations

Models: SAPPHIRE-D-CSB SAPPHIRE-D-PMH SAPPHIRE-MBK SAPPHIRE-D-MBK

1 52
Download 52 pages 31.54 Kb
Page 26
Image 26
HIGH ALTITUDE INSTALLATIONS

Manual background WARNING

Fire or Explosion Risk

Gas build-up during line purge may ignite.

Purge should be performed by qualified technician.

Ensure adequate ventilation.

Ensure there are no ignition sources such as sparks or open flame.

A small amount of air will be in the gas supply lines. When first lighting appliance it will take a short time for air to purge from the lines. When purging is complete the appli- ance will light and operate normally.

Air only needs to be purged again if the gas valve has been turned to the OFF position.

Manual background WARNING

CHECK FOR GAS LEAKS

Explosion Risk

Fire Risk

Asphyxiation Risk

Check all fittings and connections.

Do not use open flame.

After the gas line installation is complete, all connections must be tightened and checked for leaks with a commercially-available, non-corrosive leak check solution. Be sure to rinse off all leak check solution following testing.

Fittings and connections may have loosened during shipping and handling.

HIGH ALTITUDE INSTALLATIONS

Intertek Testing Lab listed gas appliances are tested and approved without requiring changes for elevations from 0 to 2000 feet in the U.S.A. and 0 to 4500 feet in Canada.

When installing this appliance at an elevation above 2000 feet, it may be necessary to decrease the input rating by changing the existing burner orifice to a smaller size. Input rate should be reduced by 4% for each 1000 feet above a 2000 foot elevation in the U.S.A. If the heating value of the gas has been reduced, these rules do not apply. To identify the proper orifice size, check with the local gas utility.

If installing this appliance in Canada at an elevation above 4500 feet, check with local authorities.

Manual backgroundWARNING

Fire Risk

Do NOT change the valve settings.

This valve has been preset at the factory.

Changing valve settings may result in fire hazard or bodily injury.

26

Quadra-Fire • Sapphire • 7055-116 Rev. D • 6/11

Page 26
Image 26