2. Rear Vent Installations:

L.Intake Fuel Restrictor Adjustment (For top or rear vent installations)

2. Rear Vent Installations:

See vent graph for recommendations on page 11 before you begin your adjustment. If your installation falls within the range of the gray shaded area of graph, it may be necessary to make an adjustment to the vertical fuel restrictor to improve the flame appearance in your appliance.

1. Top Vent Installations:

CLOSED

OPEN

Shown Fully Open

Figure 8.23 Locate the fuel restrictor adjustment on the intake plenum, accessing through the appliance front. Adjustor is centered at the top of the appliance.

Let appliance warm up before adjusting.

Loosen screws using a Phillips head screwdriver.

Pivot the vertical fuel restrictor in 1/4 in. (6mm) increments while observing the flame activity.

Turning clockwise to open fuel restrictor = less flame height and more blue in flame color.

Turning counterclockwise to close fuel restrictor = increased flame height and more yellow in flame color.

Make adjustment until flame size and activity suits your per- sonal preference, and then retighten screws on adjustment control.

Figure 8.24 The rear vent fuel restrictor is located in the back of the firebox. It is recommended to make adjustment prior to installation.

Remove the cast front, glass, logs, and brick.

Loosen screws and slide up to suggested settings (See vent graph on page 11).

Tighten screws.

Re-install cast front, glass, logs and brick.

M. Shutter Adjustment

OPENCLOSE

Figure 8.25 The shutter is located on the underside of the appliance, on the right side. To adjust the shutter, loosen the wingnut.

Moving the shutter bolt to the right closes the shutter. Moving the shutter bolt to the left, will open the shutter. Opening the shutter causes flames to become shorter and blue. Closing the shutter creates taller orange/yellow flames.

NOTE: Do not close so much as to cause a sooty flame. Improper adjustment can cause sooting in the firebox and/ or on the outside of a house with a horizontal termination.

After adjustment, tighten wingnut to lock in place.