Table 15 Temperature and Humidity Specification

Storage and Shipment

Table 16 Tape Drive Storage and Shipment Specifications

Environmental Specifications

 

 

 

Non-Operating

 

 

 

Limits (Power On,

Specification

Operating Limits

No Tape Loaded)

 

 

 

 

 

Wet Bulb

25

°C (77 °F)

25

°C (77 °F)

Temperature

 

 

 

 

 

 

 

 

 

Dry Bulb

10

°C to 40 °C

10

°C to 40 °C

Temperature Range

(50 °F to 104 °F)

(50 °F to 104 °F)

 

 

 

 

 

Temperature

11

°C (20 °F)/hour

15

°C (27 °F)/hour

Gradient

(across range)

(across range)

 

 

 

Relative Humidity

20% to 80%

10% to 90%

 

(non-condensing)

(non-condensing)

 

 

 

Humidity Gradient

10%/hour

10%/hour

 

 

 

 

 

The ambient storage and shipment environment for the tape drive may not exceed the limits shown in table 16.

 

Storage

 

 

(Unpacked or

 

Specification*

Packed)

Shipping

 

 

 

Wet Bulb

46 °C (114 °F)

46 °C (114 °F)

Temperature

 

 

 

 

 

Dry Bulb

–40 °C to 66 °C

–40 °C to 66 °C

Temperature

(–40 °F to 150 °F)

(–40 °F to 150 °F)

 

 

 

Temperature

20 °C (36 °F)/hour

20 °C (36 °F)/hour

Gradient

(across range)

(across range)

 

 

 

Relative Humidity

10 to 95%

10 to 95%

 

(non-condensing)

(non-condensing)

 

 

 

Humidity Gradient

10%/hour

10%/hour

 

 

 

Note: These specifications apply to the tape drive only. Media specifications are listed in Recording Media Specifications on page 43.