Table 15 Temperature and Humidity Specification
Storage and Shipment
Table 16 Tape Drive Storage and Shipment Specifications
Environmental Specifications
|
|
|
| |
|
|
| Limits (Power On, | |
Specification | Operating Limits | No Tape Loaded) | ||
|
|
|
|
|
Wet Bulb | 25 | °C (77 °F) | 25 | °C (77 °F) |
Temperature |
|
|
|
|
|
|
|
|
|
Dry Bulb | 10 | °C to 40 °C | 10 | °C to 40 °C |
Temperature Range | (50 °F to 104 °F) | (50 °F to 104 °F) | ||
|
|
|
|
|
Temperature | 11 | °C (20 °F)/hour | 15 | °C (27 °F)/hour |
Gradient | (across range) | (across range) | ||
|
|
| ||
Relative Humidity | 20% to 80% | 10% to 90% | ||
| ||||
|
|
| ||
Humidity Gradient | 10%/hour | 10%/hour | ||
|
|
|
|
|
The ambient storage and shipment environment for the tape drive may not exceed the limits shown in table 16.
| Storage |
|
| (Unpacked or |
|
Specification* | Packed) | Shipping |
|
|
|
Wet Bulb | 46 °C (114 °F) | 46 °C (114 °F) |
Temperature |
|
|
|
|
|
Dry Bulb | ||
Temperature | ||
|
|
|
Temperature | 20 °C (36 °F)/hour | 20 °C (36 °F)/hour |
Gradient | (across range) | (across range) |
|
|
|
Relative Humidity | 10 to 95% | 10 to 95% |
| ||
|
|
|
Humidity Gradient | 10%/hour | 10%/hour |
|
|
|
Note: These specifications apply to the tape drive only. Media specifications are listed in Recording Media Specifications on page 43.
Quantum | 42 |