Chapter 3: Installation

21

8

7

9

Fitting the low profile bezel

 

D4362-2

Flush mounting procedure

Flush mount your instrument (see the Flush mounting illustration) as follows:

1.Assemble the ST60 instrument and low-profile bezel as described under Fitting the low-profile bezel.

2.Ensure that:

The panel on which you intend to mount the instrument is between 3 mm and 20 mm thickness.

The selected location is clean, smooth and flat.

There is sufficient space behind the selected location to accom- modate the rear of the instrument and connectors.

3.Apply the flush mount template (supplied at the rear of this hand- book) to the selected location and mark out the aperture into which the assembled instrument and bezel will sit.

4.Cut out the aperture (3) for the assembled instrument and bezel and remove the template.

5.Peel off the protective sheet from the self-adhesive gasket (4) then stick the gasket into position on the rear of the bezel.

Page 33
Image 33
Raymarine ST60 Tridata manual Flush mounting procedure