Regency F37-LPG DOOR INSTALLATION Packaged Separately, Installation, A02-65 D02-46 B02-56 C02-44

Models: F37-LPG F37-NG

1 28
Download 28 pages 28.01 Kb
Page 15
Image 15
A)02-65

INSTALLATION

7)Place the Left Top Log D)02-46 on the pin on Log B)02-56 and on top of the cutout on Log A)02-65.

A)02-65

D)02-46

B)02-56

C)02-44

PinCutout

8)Place Front Right Log E)02-45 on the two pins as shown.

E)02-45

9)Place the lava rock in the area between the left and right logs, leaving a space in the middle for log (F) 02-47.

10)Place the notch in Center Log F)02-47 over Log E)02-45 and across the cutout on Log A)02-65.

F)02-47

E)02-45

11)Position notch in Front Right Log G)02-48 on Log F)02-47 and push the bottom right edge against the bracket on the burner tray.

G)02-48

A)02-65

 

47

 

F)02

-

E)02-45

 

 

 

Notch

G)02-48

E)02-45

Side View

Bracket
The bottom right edge of Log G)02-48 must sit
snugly against the bracket

12)Test fire to ensure proper light off (make sure fl ame fl ows smoothly from one end of burner to the other. If there is any fl ame hesitation, check that area for any blockage of the burner port.

 

-

 

 

 

G)02

A)02-65

D)02

46

 

 

47

-

 

 

 

 

 

 

-

 

 

48

B)02-56

F)02

 

 

 

 

 

E)02-45

C)02-44

 

 

 

 

 

 

DOOR INSTALLATION (Packaged Separately)

1)Open the two side panels.

2)Slide the door PinCutoutE)02-45

onto the two hinge pins mak-

ing sure the two pieces are fl ush together. See diagram

1.F)02-47G)02-48

3)Close the door. The latch plate must be centered around the alignment pin. See

diagram 2. If the latch Diagram 1 plate interferes with the

corner of the stove you may want to angle the plate slightly so the door closes easier.

Diagram 2

4)Thelatchesshouldalreadybeattheproper setting. If they are too hard or too easy to close, you may want to adjust them by loosening the locking nut and turning the latch catch. See diagram 3.

5)Removetheblueplasticprotectivecoating from the glass.

6)Test the seal around the door by placing a piece of paper between the unit and the door, close the door and try to pull the paper out. If it slips out easily, then the door is not properly sealed. Tighten or loosen the latch by turning the latch catch inward or outward. See diagram 3.

Note: The door latch may require adjust- ment as the door gasket material compresses after a few fires and after glass replacement. Turn the latch catch inward or outward.

Notch Cutout

Diagram 3

F37 Regency® Rear Flued Room Sealed Freestanding Gas Heater

15

Page 15