INSTALLATION

IMPORTANT

SAVE THESE

INSTRUCTIONS

The REGENCY Rear Flued Room Sealed Freestanding Gas Stove must be installed in accordanceAG601andNZS5261andwiththese instructions. Carefully read all the instructions in this manual fi rst. Consult the building authority having jurisdiction to determine the need for a permit prior to starting the installation.

Note: Failure to follow the instructions could cause a malfunction of the heater which could result in death, serious bodily injury, and/or prop- erty damage. Failure to follow these instructions may also void your fire insurance and/or warranty.

SPECIFICATIONS

Fuels: F37-NG is approved for use with NG.

F37-LPG is approved for use with liquefi ed petroleum gases (LPG).

Electrical: 240 V A.C. system.

Circulation Fan: Two Speed

Log Sets: Ceramic fi bre, 7 per set.

Flue System:

Axial (6-5/8" outer / 4" inner liner) rigid fl ue and Riser Vent Terminal.

BEFORE YOU START

Safe installation and operation of this appliance requires common sense, however, please be aware of the following:

INSTALLATION AND REPAIRS SHOULD BE DONE BY AN AU- THORIZED SERVICE PERSON. THIS APPLIANCE SHOULD BE INSTALLED, REPAIRED, IN- SPECTED BEFORE USE AND AT LEAST ANNUALLY BY AN AUTHORIZEDSERVICEPERSON. MORE FREQUENT CLEANING MAY BE REQUIRED DUE TO EX- CESSIVE LINT FROM CARPET- ING, ETC. IT IS IMPERATIVE THAT THE CONTROL COMPARTMENT, BURNERS AND CIRCULATING AIR PASSAGEWAYS OF THE AP- PLIANCE BE KEPT CLEAN.

DUE TO HIGH TEMPERATURES, THE APPLIANCE SHOULD BE LOCATED OUT OF TRAFFIC AND AWAY FROM FURNITURE AND DRAPERIES.

WARNING: FAILURE TO INSTALL THIS APPLIANCE CORRECTLY WILLVOIDYOURWARRANTYAND MAY CAUSE A SERIOUS HOUSE FIRE.

CHILDRENANDADULTS SHOULD BE ALERTED TO THE HAZARDS OF HIGH SURFACE TEMPERA- TURES, ESPECIALLY THE FIRE- PLACE GLASS, AND SHOULD STAY AWAY TO AVOID BURNS OR CLOTHING IGNITION.

YOUNG CHILDREN SHOULD BE CAREFULLY SUPERVISED WHEN THEYARE IN THE SAME ROOMAS THE APPLIANCE.

CLOTHING OR OTHER FLAM- MABLE MATERIAL SHOULD NOT BE PLACED ON OR NEAR THE APPLIANCE.

1)Provide adequate clearances for servicing, properoperationandaroundtheairopenings into the combustion chamber.

2)The appliance must be installed on a fl at, solid, continuous surface (e.g. wood, metal, concrete). This may be the fl oor, or it can be raised up on a platform to enhance its visual impact. The appliance may be installed on carpeting, tile, wood fl ooring or other combustible material, because the appliance's metal pedestal base extends the full width and depth of the appliance. The REGENCY Rear Flued Room Sealed Freestanding Gas Stove can be installed in a wide variety of ways and will fi t nearly any room layout. It may be installed in a recessed position, framed out into the room, or across a corner.

3)The REGENCY Rear Flued Room Sealed Freestanding Gas Stove is approved for manufactured home installations, see "Locating Your Gas Stove" to "Flueing Installation Precaution" sections for the re- quired fl ue arrangements. If installed into a

manufactured home the unit must be bolted down to the fl oor.

4)We recommend that you plan your instal- lation on paper using exact measurements for clearances and fl oor protection before actually installing this appliance. Have an authorized building inspector review your plans before installation.

GENERAL SAFETY

INFORMATION

1)The appliance shall be installed in accord- ance with the manufacturer's installation instructions, local gas fi tting regulations, municipal building codes, water supply regulations, electrical wiring regulations, with AS5601-2004 (AGA gas installation code) NZS 5261 (New Zealand)

2)Installation and repair should be done ONLY by an authorised person.

3)DO NOT CONNECT TO MASONARY FLUE.

4)This appliance must be connected to the specified flue and termination cap to the outside of the building envelope. Never flue to another room or inside a building. Make sure that the flue is fitted as per Flueing instructions.

5)Inspect the fl ueing system annually for blockage and any signs of deterioration.

6)Flueing terminals shall not be recessed into a wall or siding.

7)Any safety glass removed for servicing must be replaced prior to operating the ap- pliance.

8)To prevent injury, do not allow anyone who is unfamiliar with the operation to use the fi replace.

9)Wear gloves and safety glasses for protec- tion while doing required maintenance.

10)Be aware of electrical wiring locations in walls and ceilings when cutting holes for termination.

11)Under no circumstances should this ap- pliance be modifi ed. Parts that have to be removed for servicing should be replaced prior to operating this appliance.

12)Installation and any repairs to this appliance should be done by an authorised service person.Anauthorisedservicepersonshould be called to inspect this appliance annually.

F37 Regency® Rear Flued Room Sealed Freestanding Gas Heater

5

Page 5
Image 5
Regency F37-LPG, F37-NG installation manual Installation, Specifications, Before YOU Start, General Safety Information

F37-LPG, F37-NG specifications

The Regency F37-LPG and F37-NG are contemporary gas fireplaces that represent a perfect blend of modern design and efficiency, catering to both propane (LPG) and natural gas (NG) needs. These models are engineered to enhance living spaces while providing optimal warmth and comfort. Their elegant appearance and advanced technologies make them a popular choice for homeowners seeking an aesthetically pleasing and functional heating solution.

One of the key features of the Regency F37 series is its large viewing area, which allows for an unobstructed view of the flames, creating a visually stunning focal point in any room. The fireplace's design includes a clean front and minimalistic aesthetics that can complement various interior styles, from traditional to contemporary. The F37 offers an array of customizable options, including various finishes, decorative media, and fireplace configurations.

Technologically, the Regency F37 is equipped with an advanced burner system that enhances the flame presentation while maintaining high efficiency. The system produces realistic flames and glowing embers, emulating the look of a traditional wood-burning fire without the hassle of real wood. Additionally, the fireplaces feature a precise control system, allowing users to adjust the flame height and heat output according to their preferences.

In terms of efficiency, the F37 series boasts impressive energy ratings, ensuring that homeowners can enjoy warmth without incurring excessive costs. The fireplaces are designed with an emphasis on heat retention, utilizing modern insulation and venting technologies that promote optimal performance. With a focus on environmental sustainability, Regency ensures that their units produce lower emissions, making the F37 series an eco-friendly choice for heating.

The ease of installation is another significant advantage of the Regency F37, with flexible venting options designed to accommodate various home layouts. Whether it is an existing space or a new construction, the fireplace can be adapted to meet specific design and functionality needs.

In summary, the Regency F37-LPG and F37-NG are exceptional gas fireplaces that combine striking design with cutting-edge technology. Their large viewing areas, customizable options, high efficiency, and eco-friendly features make them an excellent addition to any home, ensuring comfort and style for years to come.