Regency F37-LPG, F37-NG Flueing Arrangements - Vertical Terminations, Installation, 44.5mm, 32mm

Models: F37-LPG F37-NG

1 28
Download 28 pages 28.01 Kb
Page 9
Image 9
FLUEING ARRANGEMENTS - VERTICAL TERMINATIONS

INSTALLATION

FLUEING ARRANGEMENTS - VERTICAL TERMINATIONS

for both Residential & Manufactured Homes/Mobile Homes

Vertical Terminations

with Co-linear Flex System

The shaded area in the diagram shows the allowable vertical terminations installed in a masonry chimney.All vertical fl ue instal- lations require the Flue Restrictor to be set to 32mm open. All Vertical Flue Terminals must be Simpson Dura Vent (Abey Australia) DV 980 MAS (Australian Modifi ed.)

Straight Vertical Terminations

 

9

 

 

 

8

216mm

 

 

7

 

 

 

 

(meters)Height

6

 

Max.9.1m

5

 

 

 

 

 

4

 

 

Vertical

3

1

 

 

 

 

 

 

 

 

1

 

 

2

 

Min.

 

 

 

 

1

 

3.2m

 

 

1

2

Horizontal Distance (meters)

Vertical Terminations

using Dura-Vent Flueing System

The shaded areas in the two diagrams below show all allowable com- binations of straight vertical and offset to vertical runs with vertical terminations. Maximum one 90o elbow. All vertical and offset to vertical

ue installations require Flue Restrictor to be set to 32mm open. If the fl ue is ENCLOSED in a chase (min. size 229mm x 229mm) maintain a 32mm clearance to combustibles. All Vertical Flue Terminals must be Simpson Dura Vent (Abey Australia) DV 980 MAS (Australian Modifi ed.)

Offset to Vertical Terminations

If connecting to a Dura-Vent system, the Adapter to Dura-Vent # 640-994 is required.

To set the Flue restriction as indicated in the diagram, simply loosen the screws and push the fl ue restrictor plate to the correct position. Tighten the screws.

Flue Restrictor Position

44.5mm

44.5mm

32mm

32mm

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Vent Restrictor

 

Vent Restrictor

Vent

(fully open)

Vent

 

Restrictor

 

Restrictor

 

Plate

 

Plate

 

F37 Regency® Rear Flued Room Sealed Freestanding Gas Heater