Regency F37-NG, F37-LPG installation manual Installation Checklist, Locating Your Regency Gas Stove

Models: F37-LPG F37-NG

1 28
Download 28 pages 28.01 Kb
Page 6
Image 6
INSTALLATION

INSTALLATION

Make it a practice to have all of your gas appliances checked annually.

13)Do not slam shut or strike the glass door.

14)Under no circumstances should any solid fuels (wood, paper, cardboard, coal, etc.) be used in this appliance.

15)The appliance area must be kept clear and free of combustible materials, (gases and other fl ammable vapours and liquids).

INSTALLATION

CHECKLIST

1)

Locate your gas stove. Refer to the following

 

sections where applicable:

 

a. Clearances to Combustibles

 

b. Exterior Flue Termination Locations

 

c. Planning Your Flue Installation

 

d. Flueing

 

e. Flueing Installation Precaution

2)

Install flueing. Check all fluing requirements.

 

See "Flueing" to "Vertical Termination with

 

Co-Linear Flex System" sections.

3)

Make gas connections. Refer to the "Gas

 

Connection" section.

 

Test the pilot. Must be as per diagram in the

 

"Maintenance Instruction" section.

4)

If necessary, convert from NG to LPG.

 

Refer to "Conversion Kit from NG to LPG"

 

section.

5)

Install standard and optional features. Refer

 

to the following sections where applicable.

 

a. Log Set Installation

 

b. Door Installation

 

c. Louvre Installation

 

d. Optional Wall Thermostat

 

e. Optional Remote Control

CAUTION: Any alteration to the product that causes sooting or carboning that results in damage is not the responsibility of the manufacturer.

LOCATING YOUR

REGENCY GAS STOVE

When selecting a location for your stove, ensure that the clearances listed above are met as well as ensuring that there is adequate accessibility for servicing and proper operation.

See the "Exterior Flue Termination Locations" section for Flue Termination requirements.

ThisapplianceisListedforbedroom installations when used with a Listed Millivolt Thermostat. Some areas may have further requirements, check local codes before installation.

This appliance is Listed for Alcove installations, maintain minimumAlcove clearances as follows, minimum ceiling height of 1.7m, minimum width of 1.0m and a maximum depth of 0.9m.

A)Cross Corner

B)Flush with Wall/Alcove

C)Flat on Wall Corner

D)Flat on Wall

This unit can be installed on a solid combustible surface like a wood fl oor. This unit can also be installed directly on carpeting or vinyl when the bottom pedestal cover plate (provided with unit) is installed.

Use the minimum clearances shown in the diagrams below:

F37-NG & F37-LPG Clearances

A Side Wall to Unit

190 mm

B Back Wall to Unit

76 mm

E Side Wall to Unit

114 mm

F37-NG & F37-LPG

Reference Dimensions

C Floor to Flue Centerline

635 mm

D Side Wall to Flue Centerline521 mm

Minimum ceiling height is

914mm from top of unit.

6)

Test Gas Pressure. Refer to the "Gas Pipe

 

Pressure Testing" section.

7)

Final check. Refer to the "Final Check" sec-

 

tion.

Before leaving this unit with the customer, the installer must ensure that the appliance is fi r- ing correctly and operation fully explained to customer.

This includes:

1)Clocking the appliance to ensure the correct fi ring rate (rate noted on label) after burning appliance for 15 minutes.

2)Ifrequired,adjustingtheprimaryairtoensure that the fl ame does not carbon. First allow the unit to burn for 15-20 min. to stabilize.

CLEARANCES TO

COMBUSTIBLES

The clearances listed are MINIMUM distances. Measure the clearance to both the appliance and thechimneyconnector.Thefarthestdistanceis correct if the two clearances do not coincide. For example, if the appliance is set as indicated in one of the diagrams but the connector is too close, move the stove until the correct clearance to the connector is obtained.

This appliance may be installed only with the clearances as shown in the situations pictured.

Do not combine clearances from one type of installation with another in order to achieve closer clearances.

COMBUSTION AND VENTILATION AIR

The combustion air from this appliance is drawn from outside the building through the outer fl ue.

Extra provision for combustion air inside the room is not required.

6

F37 Regency® Rear Flued Room Sealed Freestanding Gas Heater

Page 6
Image 6