Regency F37-LPG, F37-NG Exterior Flue Termination Locations, Installation, Clearance k in mm

Models: F37-LPG F37-NG

1 28
Download 28 pages 28.01 Kb
Page 7
Image 7
EXTERIOR FLUE TERMINATION LOCATIONS

INSTALLATION

EXTERIOR FLUE TERMINATION LOCATIONS

Minimum clearances required for balanced flue terminals or

the flue terminals of outdoor appliances

according to AS5601-2004 (AGA gas installation code) or NZS 5261 (New Zealand)

Minimum

Clearance (mm)

aBelow eaves, balconies or other projections:

 

- Appliances up to 50 MJ/h input

300

 

- Appliances over 50 MJ/h input

500

b

From the ground or above a balcony

300

c

From a return wall or external corner

500

d

From a gas meter (M)

1000

e

From an electricity meter or fuse box (P)

500

f

From a drain or soil pipe

150

gHorizontal from any building structure (unless appliance is approved

for closer installation) or obstruction facing a terminal

500

h From any other fl ue terminal, cowl or combustion air intake

500

jHorizontally from an openable window, door, or non-mechanical air inlet, or any other opening into a building, with the exception of sub-fl oor ventilation (see also Note (I)):

- Appliances up to 150 MJ/h input

500

- Appliances over 150 MJ/h input

1500

kVertically below an openable window, door, or non-mechanical air inlet,

or any other opening into a building, with the exception of sub-fl oor ventilation (see also Note (I)): see table below

Clearance 'k' in mm

Space Heaters

 

All Other Appliances

 

 

 

 

 

 

Up to 50 MJ/h

Up to 50 MJ/h input

Over 50 MJ/h input

 

Over 150 MJ/h input

input

 

to 150 MJ/h input

 

 

 

 

 

 

 

150

500

1000

 

1500

 

 

 

 

 

NOTES:

(I) For mechanical air inlets, including spa blowers, the clearance 'j' and 'k' shall be 1500 mm in all cases.

(II)All distances shall be measured vertically or horizontally along the wall to a point in line with the nearest par to of the terminal.

(III)Prohibited area below electricity meter or fuse box extends to ground level.

(IV)A fl ue terminal of this type shall not be located under a roofed area unless the roofed area is fully open on at least two sides and a free fl ow of air at the appliance is achieved.