INSTALLATION
FLUEING
The Regency® Room Sealed System (Horizon- tal Termination Kit
The Horiz. Termination Kit
IMPORTANT
Read all instructions carefully before starting the installation. Failure to follow these instruc- tions may create a fi re or other safety hazard, and will void the warranty. Be sure to check the
flueing and clearance to combustible require- ments in "Locating Your Regency Gas Stove" to "Flueing Installation Precaution" sections. Consult your local building codes before begin- ning installation.
Thelocationoftheterminationcapmustconform tothediagramsinthe"ExteriorFlueTerimination Locations" section.
FLUEING
INSTALLATION
PRECAUTIONS
The Regency® Room Sealed System and the Vertical Termination with the
1)Installation of any damaged Room Sealed component
2)Unauthorized modifi cation of the Room Sealed System
3)Installation of any component part not manufactured or approved by Regency® Industries Ltd.
4)Installation other than as instructed by Regency® Industries Ltd.
Warning:Always maintain required clearances (air spaces) to nearby combustibles to prevent a fire hazard. Do not fill air spaces with insulation.
The minimum clearance requirements between the outer wall of the fl ue pipe and nearby com- bustible surfaces is 30mm. Be sure to check the fl ue termination clearance requirements from decks, windows, soffi ts, gas regulators, air supply inlets and public walkways as specified in the"ExteriorFlueTerminationLocations"section and in your local building codes.
The gas appliance and flue system must be flued directly to the out- side of the building, and never be attached to a chimney serving a separate solid fuel or
Each Room Sealed gas appliance must use its own separate fl ue system. Common fl ue systems are prohibited.
SAFETY PRECAUTIONS
FOR THE INSTALLER
1)Wear gloves and safety glasses for protec- tion.
2)Exercise extreme caution when using lad- ders or on roof tops.
3)Be aware of electrical wiring locations in walls and ceilings.
PLANNING YOUR FLUEING INSTALLATION
Seethe"ExteriorFlueTerminationLocations" section for requirements.
When planning your installation, it will be nec- essary to select the proper length of fl ue pipe for your particular requirements. Determine the minimum clearance to combustibles from the rear of the unit to the wall. It is also important to note the wall thickness. Before cutting the fl ue hole through the wall ensure that ALL fl ue and termination clearances (see the "Exterior Flue Termination Locations" section) will be met.
NOTE: Ensure compliance with the outside
flue terminal location before cutting hole as both dimensions must be met.
*If this is an outside corner, the minimum distance between the fl ue and the outside corner is 12" (30cm). See "F" on the diagram in the "Exterior Flue Termination Locations" section.
For corner installation, Restrictor must | For straight rear installation, Restrictor |
be set at | must be set at |
8 | F37 Regency® Rear Flued Room Sealed Freestanding Gas Heater |