INSTALLATION
RESIDENTIAL AND MANUFACTURED HOMES /
MOBILE HOMES INSTALLATIONS
You will require the following components with your new Regency® Rear Flued Room Sealed Freestanding Gas Stove. Please review your product to make sure you have everything you need. In the event that you are missing any part, contact your dealer.
Note: These are the minimum pieces required.
Other parts may be required for your particular installation.
Minimum components for a Horizontal Installation:
1
14" dia. x 18" (102mm dia. x 457mm) Aluminum Flue
1Astro Riser Vent Terminal
1Wall Penetration Heat Shield for Heat Sensitive walls (Wall Thimble) (2 pcs)
1Decorative Wall Trim (Black)
1Tube
| Screws |
Optional Components: | |
45o Elbow - | |
| and 4" (102mm) Aluminum Flue |
Vinyl Siding Shield for Riser Vent | |
| Terminal |
Flue Guard | |
940 | Square Wall Thimble Cover* |
942Wall Penetration Heat Shield*
* Simpson
HORIZONTAL INSTALLATIONS
1) Set the unit in its desired location. Check to |
determine if wall studs are in the way when |
the fl ueing system is attached. If this is the |
case, you may want to adjust the location |
of the unit. |
2) Assemble the desired combination of pipe |
and elbow to the appliance adapter with pipe |
seams oriented down. Offset the pipe seams |
as double seams in one place will cause the |
outer pipe to take an oval shape. Kit comes |
complete with 18" (457mm) of straight fl ue |
- |
4" (102mm) dia. inner fl ue. |
c)Snorkel Terminations:
For installations requiring a vertical rise on the exterior of the building,Astro Riser Vent Terminations as shown in Dia. 2 is available. Follow the same installa- tion procedures as used for standard Horizontal Termination.
NEVERinstalltheAstroRiserventupside down.
3) With the pipe attached to the stove, slide |
the stove into its correct location, and mark |
the wall for a |
dimensions) round hole. The center of the |
round hole should line up with the centerline |
of the horizontal pipe, as shown in diagram |
1. Cut and frame the |
hole in the exterior wall where the fl ue will |
be terminated. If the wall being penetrated is |
masonry block or concrete, a 7" (178mm) |
diameter hole is acceptable. |
Diagram 1
Note:
a)The horizontal run of fl ue should have a 1/4 inch (6mm) rise for every 1 foot (305mm) of run towards the termination. Never allow the fl ue to run downward. This could cause high temperatures and may present the possibility of a fi re.
b)The location of the horizontal fl ue ter- mination on an exterior wall must meet all local and national building codes, and must not be blocked or obstructed. See the diagram in the "External Flue Termination Locations" section.
Diagram 2
*Diagram 2: Local codes or regulations may require different clearances.
10 | F37 Regency® Rear Flued Room Sealed Freestanding Gas Heater |