Regency G36D-NG NATURAL GAS Rigid Pipe Venting Systems, Horizontal or Vertical Terminations

Models: G36D-NG NATURAL GAS G36D-LP PROPANE

1 40
Download 40 pages 45.99 Kb
Page 13
Image 13
RIGID PIPE VENTING SYSTEMS

INSTALLATION

RIGID PIPE VENTING SYSTEMS

Horizontal or Vertical Terminations

The minimum components required for a basic horizontal termination are:

1Horizontal Termination Cap

190o Elbow

1Rigid Pipe Adaptor

1Wall Thimble

1Length of pipe to suit wall thickness (see chart)

Wall thickness is measured from the back standoffs to the inside mounting surface of termination cap. For siding other than vinyl furring strips may be used, instead of the vinyl siding standoff, to create a level surface to mount the vent terminal. The Terminal must not be recessed into siding. Measure the wall thickness including furring strips.

If a Vinyl Siding Standoff is required (it must be used with vinyl siding), measure to outside surface of wall without siding and add 2 inches.

Flat Wall Installation

Wall Thickness

 

Vent Length

(inches)

 

Required (inches)

 

 

 

 

 

 

4"

-

5-1/2"

 

6"

 

7" - 8-1/2"

 

9"

 

 

 

 

 

 

 

10"

-

11-1/2"

 

12"

 

 

 

 

 

 

9"

-

14-1/2"

 

11" - 14-5/8" Adj. Pipe

 

 

 

 

 

 

15"

-

23-1/2"

 

17" - 24" Adj.

 

 

 

 

 

 

 

 

 

Pipe

 

 

 

 

Corner Installation

 

Wall Thickness

 

Vent Length

(inches)

 

 

Required (inches)

3-1/4"

-

6-3/4"

 

11" - 14-5/8" Adj. Pipe

 

 

 

7-3/4" - 16-1/4"

 

17" - 24" Adj. Pipe

 

 

 

 

 

 

7-1/4"

-

8-3/4"

 

6" + 12"

 

 

 

 

 

9" + 9"

 

4-1/4"

-

5-3/4"

 

6" + 9"

 

 

 

 

 

 

 

Vertical

Terminal

Storm Collar (Part # 953)

Flashing

943 or 943S

Ceiling Firestop

(Part # 963)

Pipe Length

Vinyl Siding

Standoff (Optional)

(Part #950)

Horizontal

Termination Cap (Part# 946-523/P)

Wall Thimble (Part # 942)

Horizontal or Vertical Terminations Adj.Pipe Length

11" - 14-5/8"

90o Elbow

Alternate

Horizontal

Termination

Caps

24" Pipe

Length

Rigid Pipe Adaptor

(Part# 510-994)

WARNING:

Do not combine venting components from different venting systems.

However use of the the AstroCapTM and FPI Riser is acceptable with all systems.

This product has been evaluated by Intertek for using a Dura-Vent Flue Adaptor in conjunction with Selkirk Direct-Temp and Ameri Vent Direct venting systems. Use of these systems with the Direct Vent GS starting collar is deemed accept- able and does not affect the Intertek WHI listing of components.

When using piping other than Simpson Dura-Vent, 3 screws must be used to secure rigid pipe to adaptor.

The FPI AstroCapTM and FPI Riser Vent terminal is certifi ed for installations using FPI venting systems as well as Simpson Dura-Vent®, Direct Vent GS, American Metal Products, Ameri Vent Direct vent and Selkirk Direct-Temp. FPITM, and FPI AstroCapTM are the proprietary trademarks of FPI Fireplace Products International Ltd. Dura-Vent® and Direct Vent GS are registered and/or proprietary trademarks of Simpson Dura-Vent Co. Inc.

UltraGlow G36D Zero Clearance Direct Vent Gas Fireplace

13

Page 13
Image 13
Regency G36D-NG NATURAL GAS Rigid Pipe Venting Systems, Horizontal or Vertical Terminations, Installation, Storm Collar