MAINTENANCE

4)Make a periodic check of burner for proper position and condition. Visually check the flame of the burner periodically, making sure the fl ames are steady; not lifting or fl oating. If there is a problem, call a qualifi ed service person.

5)The appliance and venting system must be inspected before use, and at least annually, by a qualifi ed fi eld service person, to ensure that the fl ow of combustion and ventilation air is not obstructed.

Note: Never operate the appliance with- out the glass properly secured in place.

6)Donotusethisapplianceifanyparthasbeen under water. Immediately call a qualifi ed service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water.

7)Verify operation after servicing.

General Vent Maintenance

Conduct an inspection of the venting system semi-annually. Recommended areas to inspect as follows:

1) Check the Venting System for corrosion in

areas that are exposed to the elements.

These will appear as rust spots or streaks,

and in extreme cases, holes. These com-

ponents should be replaced immediately.

2) Remove the Cap, and shine a fl ashlight

down the Vent. Remove any bird nests, or

other foreign material.

3) Checkforevidencesofexcessivecondensa-

tion, such as water droplets forming in the

innerliner,andsubsequentlydrippingoutthe

joints, Continuous condensation can cause

corrosion of caps, pipe, and fi ttings. It may

be caused by having excessive lateral runs,

toomanyelbows,andexteriorportionsofthe

system being exposed to cold weather.

Clean any fingerprints off before turning the unit on. If the top louvers start to discolour, check the door gasket seal and replace if necessary.

LOG REPLACEMENT

The unit should never be used with broken logs. Turn off the gas valve and allow the unit to cool before opening door and carefully remove the logs. (The pilot light generates enough heat to burn someone.) If for any reason a log should need replacement, you must use the proper replacement log. The position of these logs must be as shown in the diagrams under Log Installation.

Note: Improper positioning of logs may cre- ate carbon build-up and will severely alter the unit's performance which is not covered under warranty.

THERMOPILE/

THERMOCOUPLE

1)Open the bottom louvers.

2)Loosen the thermocouple or thermopile with a 7/16" wrench.

3)Disconnect thermocouple by loosening nut from the valve with a 9mm wrench. Dis- connect thermopile by loosening 2 screws marked TP on the valve.

4)Drop the thermocouple or thermopile down from the bracket and pull it out of the unit.

5)Reinstall the new ones in reverse order.

GLASS GASKET

If the glass gasket requires replacement use a tadpole glass gasket for the Flush Front (Part

# 936-155).

WARNING:Donotoperatetheappliance with the glass panels removed, cracked or broken. Replacement of the glass panels should be done by a licensed or qualified service person.

Caution: Wear gloves when removing damaged or broken glass.

Flush Glass Replacement

Remove the fl ush door front (as per instructions on page 28). Remove the 4 glass clips from each corner.Slideinthenewreplacementglass.Push the 4 glass clips back onto the frame. The glass must have gasketing around it.

4) Inspect joints, to verify that no pipe sections

or fi ttings have been disturbed, and conse-

quently loosened. Also check mechanical

supports such as Wall Straps, or plumbers'

tape for rigidity.

GOLD-PLATED

OR BRASS TRIM

The 24 carat gold plated or brass fi nish on the trim requires little maintenance, and need only be cleaned with a damp cloth. DO NOT use abrasive materials or chemical cleaners, as they may harm the fi nish and void the warranty.

DOOR GLASS

Your UltraGlow stove is supplied with high tem- perature,5mmtemperedglassthatwillwithstand the highest heat that your unit will produce. If your glass requires cleaning, we recommend using an approved glass cleaner available at all authorized dealers. Do not use abrasive materi- als. Do not clean the glass when hot.

In the event that you break your glass by impact, purchase your replacement from an authorized UltraGlow dealer only, and follow our step-by- step instructions for replacement.

34

UltraGlow G36D Zero Clearance Direct Vent Gas Fireplace

Page 34
Image 34
Regency G36D-LP PROPANE, G36D-NG NATURAL GAS installation manual Maintenance

G36D-NG NATURAL GAS, G36D-LP PROPANE specifications

The Regency G36D-LP Propane and G36D-NG Natural Gas fireplaces are exemplary models designed to enhance both aesthetic appeal and functional warmth in any home. These innovative units are perfect for individuals looking to add a touch of elegance while enjoying the convenience of modern fireplace technology.

One of the primary features of the G36D series is its impressive heating capability, which can produce up to 34,000 BTUs, making it effective for warming large living spaces. This efficiency is complemented by their design, which allows for rapid heat distribution, ensuring that the warmth is felt throughout the room.

Both models are available in propane and natural gas options, providing flexibility based on user preference or availability. The G36D-LP utilizes propane, making it ideal for homes without a natural gas line, while the G36D-NG is suitable for those connected to a natural gas supply. This adaptability allows homeowners to choose the most economical and convenient fuel source for their needs.

A standout characteristic of the G36D series is its clean, contemporary design. The fireplace features large viewing windows that are bordered by an elegant frame, offering an unobstructed view of the flames. The realistic log set and glowing embers create a visually stunning fire experience that mimics the ambiance of a traditional wood-burning fireplace without the associated maintenance.

The fireplaces are also equipped with state-of-the-art technology, including a reliable electronic ignition system, which ensures easy starts every time while enhancing safety. The G36D series features adjustable flame height settings, allowing users to customize their experience based on preference or room ambiance.

In terms of efficiency, the G36D fireplaces boast an annual fuel utilization efficiency (AFUE) rating that meets modern energy standards. This characteristic not only contributes to environmental sustainability but also results in lower utility costs over time.

Moreover, the G36D series is designed with a user-friendly interface, allowing homeowners to operate their fireplace with ease. With optional remote controls and wall switches available, adjusting the settings has never been more convenient.

The Regency G36D-LP and G36D-NG are perfect for those who seek the charm of a fireplace with the benefits of modern innovation. Their blend of aesthetic appeal, advanced technology, and efficient heating makes them a standout choice for any homeowner looking to enhance their living space.