Regency G36D-NG NATURAL GAS Option REMOTE CONTROL, Option WALL SWITCH, Option WALL THERMOSTAT

Models: G36D-NG NATURAL GAS G36D-LP PROPANE

1 40
Download 40 pages 45.99 Kb
Page 29
Image 29
Option 1:

INSTALLATION

Option 1:

REMOTE CONTROL

Use the UltraGlow Remote Control Kit approved for this unit. Use of other systems may void your warranty.

The remote control kit comes with a hand held transmitter, a receiver and a wall mounting plate.

1)Choose a convenient location on the wall to install the receiver and the receptacle box (protection from extreme heat is very important). Run wires from the fi replace to that location. Use the Thermostat Wire Table.

2)Connect the two wires to the gas valve. See diagram below.

Option 2:

WALL SWITCH

1)Run the wire through the right or left side inlet opening. Be careful not to damage wire.

Note: We recommend a maximum of 15' of wire but if you wish to go with a longer run, use the Thermostat Wire Table.

2)Connect the wire to the wall switch and install into the receptacle box.

CAUTION

Do not connect millivolt

wall switch wire to a 120V wire.

Option 3:

WALL THERMOSTAT

A wall thermostat may be installed if desired, connect the wires as per the wiring diagram. Use the table below to determine the maximum wire length.

Note: Preferable if the thermostat is installed on an interior wall.

UltraGlow offers an optional programmable thermostat or basic wall thermostat but any 250-750 millivolt rated non-anticipator type thermostat that is CSA, ULC or UL approved may be used.

CAUTION

Do not connect millivolt

wall thermostat wires

to a 120V wire.

CAUTION

Do not connect millivolt remote

control wires to a 120V wire.

3)Install 3AAAalkaline batteries in transmitter and 4 AA alkaline batteries in the receiver. Install the receiver and its cover in the wall. Switch the remote receiver to "remote" mode. The remote control is now ready for operation.

Thermostat Wire Table

Recommended Maximum Lead Length

(Two-Wire) When Using Wall

Thermostat (CP-2 System)

Wire Size

Max. Length

 

 

 

 

 

14 GA.

50

Ft.

 

16 GA.

32

Ft.

 

18 GA.

20

Ft.

 

20 GA.

12

Ft.

 

22 GA.

9

Ft.

 

 

 

 

 

UltraGlow G36D Zero Clearance Direct Vent Gas Fireplace

29

Page 29
Image 29