INSTALLATION
This includes:
1)Clocking the appliance to ensure the correct fi ring rate (rate noted on label 26,000 Btu/h) after burning appliance for 15 minutes.
2)Ifrequired,adjustingtheprimaryairtoensure that the fl ame does not carbon. First allow the unit to burn for
CAUTION: Any alteration to the product that causes sooting or carboning that results in damage is not the responsibility of the manufacturer.
LOCATING YOUR
GAS STOVE
5)This appliance is Listed for bedroom instal- lations when used with a Listed Millivolt Thermostat. Some areas may have further requirements, check local codes before installation.
6)The G36D Direct Vent Gas Fireplace is approved for alcove installations, which meet the clearances listed on this page.
7)We recommend that you plan your instal- lation on paper using exact measurements for clearances and fl oor protection before actually installing this appliance. Have a qualified inspector, dealer, or installer review your plans before installation.
Note: For vent terminations see page 10.
MANUFACTURED
MOBILE HOME
ADDITIONAL
REQUIREMENTS
1)Ensure that structural members are not cut or weakened during installation.
2)Ensure proper grounding using the #8 ground lug provided. See page 29.
1)When selecting a location for your stove, ensure that the clearances outlined on this page are met.
2)Provide adequate clearances for servic- ing.
3)The appliance must be installed on a fl at, solid, continuous surface (e.g. wood, metal, concrete).This may be the floor, or raised up on a platform to enhance its visual impact. If the appliance is going to be installed on carpeting, combustible linoleum tile or other combustible material other than wood fl oor- ing, the appliance must be installed on a metal or wood panel extending the full width and depth of the appliance.
4)The G36D Direct Vent Gas Fireplace can be installed in a recessed position or framed out into the room as in A, B, C, D. See Diagram 1.
A)Flat on Wall
B)Flat on Wall Corner
C)Recessed into Wall/Alcove
D)Corner
G36D UNIT DIMENSIONS |
Diagram 1
6 | UltraGlow G36D Zero Clearance Direct Vent Gas Fireplace |