•Vent must be supported at offsets

INSTALLATION

RIDID PIPE VENTING ARRANGEMENTS - VERTICAL TERMINATIONS

(Propane & Natural Gas)

The G36D is approved for a maximum 23 ft. (7.0m) vertical, with a maximum 12 ft. (3.7m) horizontal offset using two 90o elbows (two 45o elbows equal one 90o elbow) with Rigid Pipe vent systems for Propane and Natural Gas, as per diagram 1.

The G36D is approved for a maximum 37 ft. (11.3m) straight vertical, including a maximum 20" (0.5m) horizontal offset using two 90o elbow (two 45o elbows equal one 90o elbow) with Rigid Pipe vent systems for Propane and Natural Gas, as per the diagram 2.

Vent must be supported at offsets

Maintain clearances to combustibles as listed on pages 7 and 8.

Firestops are required at each floor level and whenever passing through a wall.

Note: Must use optional rigid pipe adaptor when using rigid pipe vent systems (Part # 510-994).

Note: UltraGlow Direct Vent System (Flex) is only approved for horizontal terminations.